Calf milk replacers are low-cost feeds that contain available, digestible protein. During their reconstitution, however, the addition of drugs, such as antibiotics, could make them a very simple route for illicit treatment for therapeutic, preventive, or growth-promoting purposes. We developed an HPLC-MS/MS method, preceded by a unique extraction step, able to identify 17 antibiotics from seven classes (penicillins, tetracyclines, fluoroquinolones, sulfonamides, cephalosporins, amphenicols, and lincosamides) in this matrix. Prior to solid phase extraction (SPE), the sample underwent deproteinization and defatting. The method was fully validated according to Commission Decision 2002/657/EC. Decision limits (CCα) and detection capability (CCβ) were in the ranges of 0.13-1.26 and 0.15-1.47 ng/mL, respectively. Thirty-eight samples were finally analyzed, showing the occasional presence of marbofloxacin (six samples) and amoxicillin (one sample).
A liquid chromatography-tandem mass spectrometry method for the detection of antimicrobial agents from seven classes in calf milk replacers: validation and application / L.M. Chiesa, M. Nobile, S. Panseri, B. Biolatti, F.T. Cannizzo, R. Pavlovic, F. Arioli. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - 64:12(2016), pp. 2635-2640. [10.1021/acs.jafc.6b00155]
A liquid chromatography-tandem mass spectrometry method for the detection of antimicrobial agents from seven classes in calf milk replacers: validation and application
L.M. ChiesaPrimo
;M. NobileSecondo
;S. Panseri
;R. PavlovicPenultimo
;F. ArioliUltimo
2016
Abstract
Calf milk replacers are low-cost feeds that contain available, digestible protein. During their reconstitution, however, the addition of drugs, such as antibiotics, could make them a very simple route for illicit treatment for therapeutic, preventive, or growth-promoting purposes. We developed an HPLC-MS/MS method, preceded by a unique extraction step, able to identify 17 antibiotics from seven classes (penicillins, tetracyclines, fluoroquinolones, sulfonamides, cephalosporins, amphenicols, and lincosamides) in this matrix. Prior to solid phase extraction (SPE), the sample underwent deproteinization and defatting. The method was fully validated according to Commission Decision 2002/657/EC. Decision limits (CCα) and detection capability (CCβ) were in the ranges of 0.13-1.26 and 0.15-1.47 ng/mL, respectively. Thirty-eight samples were finally analyzed, showing the occasional presence of marbofloxacin (six samples) and amoxicillin (one sample).File | Dimensione | Formato | |
---|---|---|---|
Revised Antibiotics in milk replacers March 2016.pdf
accesso riservato
Descrizione: manoscritto inviato dopo le correzioni suggerite dai referee
Tipologia:
Pre-print (manoscritto inviato all'editore)
Dimensione
3.68 MB
Formato
Adobe PDF
|
3.68 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
acs%2Ejafc%2E6b00155.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
1.45 MB
Formato
Adobe PDF
|
1.45 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.