Infrared (IR) technology offers a promising solution for reducing microbiological loads in various food types while preserving their quality traits, such as flavour. However, research on IR's application in complex matrices is limited. Therefore, our preliminary study aimed to evaluate its effectiveness in sanitizing bovine raw milk. We assessed the bacterial count before and after IR treatment by comparing volatile organic compound profiles via headspace extraction and GC/MS analysis. Our findings showed that higher energy levels led to a greater bacterial reduction. IR85 was the most effective in reducing Coliforms and Enterobacteriaceae in non-homogenised samples, with a reduction ranging from -1.01 to >-2.99 and from -1.66 to -3.09 Log CFU/mL, respectively. IR60 and 70 showed no efficacy, while IR80 had intermediate but still satisfactory effect. IR85 notably affected volatile compounds, particularly increasing hexanal (from 0.08 to 4.21 ng g(-1)) and dimethyl sulphone (from 10.76 to 26.40 ng g(-1)), while IR80 better preserved the aroma profile. As a result, only IR80 was tested with homogenised raw milk, demonstrating significant bacterial reduction (from >2.39 to 3.06 Log CFU/mL for Coliforms and from 1.90 to >2.45 Log CFU/mL for Enterobacteriaceae) and maintaining the aroma profile quality.

Preliminary Investigation towards the Use of Infrared Technology for Raw Milk Treatment / L. Danesi, M. Nobile, M. Fontana, E. Tirloni, L.M. Chiesa, F. Savini, R.E. Villa, S. Panseri. - In: FOODS. - ISSN 2304-8158. - 13:7(2024 Apr 06), pp. 1117.1-1117.12. [10.3390/foods13071117]

Preliminary Investigation towards the Use of Infrared Technology for Raw Milk Treatment

L. Danesi
Primo
;
M. Nobile
Secondo
;
M. Fontana;E. Tirloni
;
L.M. Chiesa;R.E. Villa
Penultimo
;
S. Panseri
Ultimo
2024

Abstract

Infrared (IR) technology offers a promising solution for reducing microbiological loads in various food types while preserving their quality traits, such as flavour. However, research on IR's application in complex matrices is limited. Therefore, our preliminary study aimed to evaluate its effectiveness in sanitizing bovine raw milk. We assessed the bacterial count before and after IR treatment by comparing volatile organic compound profiles via headspace extraction and GC/MS analysis. Our findings showed that higher energy levels led to a greater bacterial reduction. IR85 was the most effective in reducing Coliforms and Enterobacteriaceae in non-homogenised samples, with a reduction ranging from -1.01 to >-2.99 and from -1.66 to -3.09 Log CFU/mL, respectively. IR60 and 70 showed no efficacy, while IR80 had intermediate but still satisfactory effect. IR85 notably affected volatile compounds, particularly increasing hexanal (from 0.08 to 4.21 ng g(-1)) and dimethyl sulphone (from 10.76 to 26.40 ng g(-1)), while IR80 better preserved the aroma profile. As a result, only IR80 was tested with homogenised raw milk, demonstrating significant bacterial reduction (from >2.39 to 3.06 Log CFU/mL for Coliforms and from 1.90 to >2.45 Log CFU/mL for Enterobacteriaceae) and maintaining the aroma profile quality.
food safety; green transition; infrared radiation; milk; sustainability
Settore VET/04 - Ispezione degli Alimenti di Origine Animale
6-apr-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
Preliminary latte IR_foods-13-01117.pdf

accesso aperto

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 268.31 kB
Formato Adobe PDF
268.31 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1049049
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact