An improved method for determination of 2-dodecylcylobutanone (DCB) in irradiated ground beef patties was developed. This method is based on a head-space solid-phase microextraction (HS-SPME) technique followed by gas-chromatography-mass-spectrometry (GC/MS) detection. SPME conditions were optimised: time and temperature for the adsorption of DCB on the polydimethylsiloxane (PDMS) fiber were set at 60 min and 80 degrees C, respectively. A matrix-matched standard calibration in the range 5-150 ppb was carried out, using 2-pentylcyclopentanone as internal standard. Linearity (r(2) = 0.9999), repeatability (8.4%), intermediate precision (13.6%), limit of detection (LOD) (1.5 ppb), lower limit of quantification (LLOQ) (5 ppb) demonstrated that the analytical procedure is fully reliable. The method was applied to irradiated samples in order to evaluate the dose-response effects. The concentration of DCB was quantified in beef patties irradiated at doses as low as 0.5 kGy and was linearly increased up to 8 kGy.

Improved determination of 2-dodecylcyclobutanone in irradiated ground beef patties by gas-chromatography mass-spectrometry (GC/MS) coupled with solidphase microextraction (SPME) technique / S. Soncin, S. Panseri, M. Rusconi, M. Mariani, L.M. Chiesa, P.A. Biondi. - In: FOOD CHEMISTRY. - ISSN 0308-8146. - 134:1(2012 Sep 01), pp. 440-444. [10.1016/j.foodchem.2012.02.089]

Improved determination of 2-dodecylcyclobutanone in irradiated ground beef patties by gas-chromatography mass-spectrometry (GC/MS) coupled with solidphase microextraction (SPME) technique

S. Soncin
Primo
;
S. Panseri
Secondo
;
M. Rusconi;L.M. Chiesa
;
P.A. Biondi
Ultimo
2012

Abstract

An improved method for determination of 2-dodecylcylobutanone (DCB) in irradiated ground beef patties was developed. This method is based on a head-space solid-phase microextraction (HS-SPME) technique followed by gas-chromatography-mass-spectrometry (GC/MS) detection. SPME conditions were optimised: time and temperature for the adsorption of DCB on the polydimethylsiloxane (PDMS) fiber were set at 60 min and 80 degrees C, respectively. A matrix-matched standard calibration in the range 5-150 ppb was carried out, using 2-pentylcyclopentanone as internal standard. Linearity (r(2) = 0.9999), repeatability (8.4%), intermediate precision (13.6%), limit of detection (LOD) (1.5 ppb), lower limit of quantification (LLOQ) (5 ppb) demonstrated that the analytical procedure is fully reliable. The method was applied to irradiated samples in order to evaluate the dose-response effects. The concentration of DCB was quantified in beef patties irradiated at doses as low as 0.5 kGy and was linearly increased up to 8 kGy.
Irradiation; Ground beef; DCB; HS-SPME; GC/MS
Settore VET/04 - Ispezione degli Alimenti di Origine Animale
1-set-2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0308814612002774-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 278.42 kB
Formato Adobe PDF
278.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/171550
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 16
social impact