Introduction: The misuse of antimicrobials (AMs) in poultry production contributes significantly to the global threat of antimicrobial resistance. Despite legislative efforts within the European Union (EU) to reduce AM use, Italy remains among the countries with the highest consumption levels. Effective and accessible screening tools for AMs residues in poultry meat are crucial for food safety monitoring and regulatory compliance. This study evaluates the performance of the Beadyplex flow cytometric assay as a field-applicable method to detect residues of thiamphenicol, sulphadiazine, and amoxicillin in broiler chicken skeletal muscle. Methods: Pectoralis major muscle samples were collected from 41 male broiler chickens (Ross 308) previously treated with thiamphenicol (n = 11), sulphadiazine (n = 6), amoxicillin (n = 12), or untreated (controls, n = 12). Beadyplex assays were performed following manufacturer instructions, and results were acquired using a standard flow cytometer. Sensitivity, specificity, predictive values, and kappa agreement were calculated to assess the performance of the test in recognizing the AMs treatment. The agreement with the current reference method for detecting AM residues (high-performance liquid chromatography–high-resolution mass spectrometry, or HPLC-HRMS) was also calculated. Results: The Beadyplex assay demonstrated high sensitivity and specificity for thiamphenicol (Se = 1.00; Sp = 0.83; k = 0.791) and sulphadiazine (Se = 1.00; Sp = 0.91; k = 0.813), with substantial to almost perfect agreement with HPLC-HRMS results (k = 0.706 and 0.827, respectively). Amoxicillin residues were not detected in any treated sample by Beadyplex. Discussion: The Beadyplex assay offers a promising, cost-effective, and rapid screening complementary to confirmatory analysis for detecting selected AM residues in poultry meat. Its substantial agreement with reference methods and ease of use with standard cytometers support its potential application in field-based veterinary surveillance and food safety programs.

Rapid detection of antimicrobial residues in broiler meat using flow cytometry-driven multiplex immunoassay / F.T. Cannizzo, F. Sini, S. Divari, M. Cuccato, A. Poggi, S. Panseri, M. Nobile, L.M. Chiesa, F. Riondato. - In: FRONTIERS IN VETERINARY SCIENCE. - ISSN 2297-1769. - 12:(2025 Oct 30), pp. 1636223.1-1636223.7. [10.3389/fvets.2025.1636223]

Rapid detection of antimicrobial residues in broiler meat using flow cytometry-driven multiplex immunoassay

S. Panseri;M. Nobile;L.M. Chiesa
Penultimo
;
2025

Abstract

Introduction: The misuse of antimicrobials (AMs) in poultry production contributes significantly to the global threat of antimicrobial resistance. Despite legislative efforts within the European Union (EU) to reduce AM use, Italy remains among the countries with the highest consumption levels. Effective and accessible screening tools for AMs residues in poultry meat are crucial for food safety monitoring and regulatory compliance. This study evaluates the performance of the Beadyplex flow cytometric assay as a field-applicable method to detect residues of thiamphenicol, sulphadiazine, and amoxicillin in broiler chicken skeletal muscle. Methods: Pectoralis major muscle samples were collected from 41 male broiler chickens (Ross 308) previously treated with thiamphenicol (n = 11), sulphadiazine (n = 6), amoxicillin (n = 12), or untreated (controls, n = 12). Beadyplex assays were performed following manufacturer instructions, and results were acquired using a standard flow cytometer. Sensitivity, specificity, predictive values, and kappa agreement were calculated to assess the performance of the test in recognizing the AMs treatment. The agreement with the current reference method for detecting AM residues (high-performance liquid chromatography–high-resolution mass spectrometry, or HPLC-HRMS) was also calculated. Results: The Beadyplex assay demonstrated high sensitivity and specificity for thiamphenicol (Se = 1.00; Sp = 0.83; k = 0.791) and sulphadiazine (Se = 1.00; Sp = 0.91; k = 0.813), with substantial to almost perfect agreement with HPLC-HRMS results (k = 0.706 and 0.827, respectively). Amoxicillin residues were not detected in any treated sample by Beadyplex. Discussion: The Beadyplex assay offers a promising, cost-effective, and rapid screening complementary to confirmatory analysis for detecting selected AM residues in poultry meat. Its substantial agreement with reference methods and ease of use with standard cytometers support its potential application in field-based veterinary surveillance and food safety programs.
Beadyplex; HPLC-HRMS; antimicrobials; flow cytometry; immunoassay;
Settore MVET-02/B - Ispezione degli alimenti di origine animale
30-ott-2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
fvets-12-1636223.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 664.79 kB
Formato Adobe PDF
664.79 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1202756
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact