An analytical method based on ultrasound assisted extraction (UAE) and liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI/MS/MS) was validated and applied for determining L-dopa in four ecotypes of Fagioli di Sarconi beans (Phaseolus vulgaris L.), marked with the European label PGI (Protected Geographical Indication). The selectivity of the proposed method was ensured by the specific fragmentation of the analyte. Simple isocratic chromatographic conditions and mass spectrometric detection in multiple reaction monitoring (MRM) acquisition mode were used for sensitive quantification. The LC-ESI/MS/MS method was validated within a linear range of 0.001-5.000 microg/mL. Values of 0.4 and 1.1 ng/mL were obtained for the limits of detection and quantification, respectively. The repeatability, inter-day precision, and recovery values ranges were 0.6%-4.5%, 5.4%-9.9%, and 83%-93%, respectively. Fresh and dried beans, as well as pods, cultivated exclusively with organic methods avoiding any synthetic fertilizers and pesticides were analyzed showing an L-dopa content ranging from 0.020 +/- 0.005 to 2.34 +/- 0.05 microg/g dry weight.

A validated LC-MS/MS method for quantitative determination of L-dopa in Fagioli di Sarconi beans (Phaseolus vulgaris L.) / C. Tesoro, F. Lelario, R. Ciriello, G. Bianco, M.A. Acquavia, P. Montoro, M.A. Crescenzi, E. Gregori, M. Dell'Agli, S. Piazza, A. Guerrieri, A. Di Capua. - In: JOURNAL OF MASS SPECTROMETRY. - ISSN 1076-5174. - (2023), pp. e4952.1-e4952.8. [Epub ahead of print] [10.1002/jms.4952]

A validated LC-MS/MS method for quantitative determination of L-dopa in Fagioli di Sarconi beans (Phaseolus vulgaris L.)

M. Dell'Agli;S. Piazza;
2023

Abstract

An analytical method based on ultrasound assisted extraction (UAE) and liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI/MS/MS) was validated and applied for determining L-dopa in four ecotypes of Fagioli di Sarconi beans (Phaseolus vulgaris L.), marked with the European label PGI (Protected Geographical Indication). The selectivity of the proposed method was ensured by the specific fragmentation of the analyte. Simple isocratic chromatographic conditions and mass spectrometric detection in multiple reaction monitoring (MRM) acquisition mode were used for sensitive quantification. The LC-ESI/MS/MS method was validated within a linear range of 0.001-5.000 microg/mL. Values of 0.4 and 1.1 ng/mL were obtained for the limits of detection and quantification, respectively. The repeatability, inter-day precision, and recovery values ranges were 0.6%-4.5%, 5.4%-9.9%, and 83%-93%, respectively. Fresh and dried beans, as well as pods, cultivated exclusively with organic methods avoiding any synthetic fertilizers and pesticides were analyzed showing an L-dopa content ranging from 0.020 +/- 0.005 to 2.34 +/- 0.05 microg/g dry weight.
L-dopa; LC-MS/MS; beans; quantitative analysis; validation
Settore BIO/14 - Farmacologia
2023
lug-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
2023_Journal of Mass Spectrometry.pdf

accesso riservato

Descrizione: Research Article
Tipologia: Publisher's version/PDF
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/989748
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact