BACKGROUND: In the era of screening colonoscopy, assessment of operator competence is warranted. AIM: To evaluate feasibility of a computer simulator (CS) use for assessment of competence in colonoscopy by investigating performance of expert endoscopists at CS. SUBJECTS: Twenty expert endoscopists involved in screening colonoscopy. METHODS: Experts returned a questionnaire regarding personal practice (duration of activity, number of colonoscopies in the last year and assistance by a nurse) and performances (percentage of caecal intubation and polyp detection rate). One easy and one difficult colonoscopy were proposed at CS in randomized order. RESULTS: Participation rate was 75%. Caecal intubation rate in clinical practice was more than 90% for all experts. At CS, time to caecal intubation and number of attempts for ileal intubation were significantly lower during easy versus difficult colonoscopy (P<0.01 for both items); interestingly, percentage of mucosa explored was higher (P<0.05) during the difficult simulation. Withdrawal time >/=6 min was achieved by 40 and 33% of experts during the easy and difficult simulation, respectively. Independent of simulation difficulty, time with loop was lower (P<0.05) for experts using hands-free insertion (n = 8) compared with those using nurse assistance in their clinical practice (n = 7). No correlation was found between scores at CS and performance in clinical practice. CONCLUSION: Scores at CS are sensitive to the rate of technical difficulty and nurse assistance during daily practice. Withdrawal time is often shorter than required for high accuracy in polyp detection. CS could be a well-accepted tool for assessment of competence

Computer simulator among experts involved in screening colonoscopy / P. Cantù, A. Grigolon, C. Caparello, I. Bravi, A. Tenca, A. Elvevi, M.T. Nicita, P. Duca, D. Conte, R. Penagini. - In: EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY. - ISSN 0954-691X. - 22:1(2010 Jan), pp. 61-66. [10.1097/MEG.0b013e32832ad615]

Computer simulator among experts involved in screening colonoscopy

P. Cantù
Primo
;
A. Grigolon
Secondo
;
C. Caparello;I. Bravi;A. Tenca;P. Duca;D. Conte
Penultimo
;
R. Penagini
Ultimo
2010

Abstract

BACKGROUND: In the era of screening colonoscopy, assessment of operator competence is warranted. AIM: To evaluate feasibility of a computer simulator (CS) use for assessment of competence in colonoscopy by investigating performance of expert endoscopists at CS. SUBJECTS: Twenty expert endoscopists involved in screening colonoscopy. METHODS: Experts returned a questionnaire regarding personal practice (duration of activity, number of colonoscopies in the last year and assistance by a nurse) and performances (percentage of caecal intubation and polyp detection rate). One easy and one difficult colonoscopy were proposed at CS in randomized order. RESULTS: Participation rate was 75%. Caecal intubation rate in clinical practice was more than 90% for all experts. At CS, time to caecal intubation and number of attempts for ileal intubation were significantly lower during easy versus difficult colonoscopy (P<0.01 for both items); interestingly, percentage of mucosa explored was higher (P<0.05) during the difficult simulation. Withdrawal time >/=6 min was achieved by 40 and 33% of experts during the easy and difficult simulation, respectively. Independent of simulation difficulty, time with loop was lower (P<0.05) for experts using hands-free insertion (n = 8) compared with those using nurse assistance in their clinical practice (n = 7). No correlation was found between scores at CS and performance in clinical practice. CONCLUSION: Scores at CS are sensitive to the rate of technical difficulty and nurse assistance during daily practice. Withdrawal time is often shorter than required for high accuracy in polyp detection. CS could be a well-accepted tool for assessment of competence
Computer simulator; Screening colonoscopy; Virtual endoscopy
Settore MED/01 - Statistica Medica
Settore MED/12 - Gastroenterologia
gen-2010
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/71851
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact