Background--Only a few studies have systematically evaluated fluoroscopy data of electrophysiological and device implantation procedures. Aims of this study were to quantify ionizing radiation exposure for electrophysiological/device implantation procedures in a large series of patients and to analyze the x-ray exposure trend over years and radiation exposure in patients undergoing atrial fibrillation ablation considering different technical aspects. Methods and Results--We performed a retrospective analysis of all electrophysiological/device implantation procedures performed during the past 7 years in a modern, large-volume laboratory. We reported complete fluoroscopy data on 8150 electrophysiological/device implantation procedures (6095 electrophysiological and 2055 device implantation procedures); for each type of procedure, effective dose and lifetime attributable risk of cancer incidence and mortality were calculated. Over the 7-year period, we observed a significant trend reduction in fluoroscopy time, dose area product, and effective dose for all electrophysiological procedures (P < 0.001) and a not statistically significant trend reduction for device implantation procedures. Analyzing 2416 atrial fibrillation ablations, we observed a significant variability of fluoroscopy time, dose area product and effective dose among 7 different experienced operators (P < 0.0001) and a significant reduction of fluoroscopy use over time (P < 0.0001) for all of them. Considering atrial fibrillation ablation techniques, fluoroscopy time was not different (P = 0.74) for radiofrequency catheter ablation in comparison with cryoablation, though cryoablation was still associated with higher dose area product and effective dose values (P < 0.001). Conclusions--Electrophysiological procedures involve a nonnegligible x-ray use, leading to an increased risk of malignancy. Awareness of radiation-related risk, together with technological advances, can successfully optimize fluoroscopy use.

X-ray exposure in cardiac electrophysiology: A retrospective analysis in 8150 patients over 7 years of activity in a modern, large-volume laboratory / M. Casella, A.D. Russo, E. Russo, V. Catto, F. Pizzamiglio, M. Zucchetti, B. Majocchi, S. Riva, G. Vettor, M.A. Dessanai, G. Fassini, M. Moltrasio, F. Tundo, C. Vignati, S. Conti, A. Bonomi, C. Carbucicchio, L. Di Biase, A. Natale, C. Tondo. - In: JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE. - ISSN 2047-9980. - 7:11(2018 Jun). [10.1161/JAHA.117.008233]

X-ray exposure in cardiac electrophysiology: A retrospective analysis in 8150 patients over 7 years of activity in a modern, large-volume laboratory

A. DELLO RUSSO;F. Pizzamiglio;M. Zucchetti;B. Majocchi;M.A. Dessanai;F. Tundo;C. Vignati;A. Natale;C. Tondo
2018

Abstract

Background--Only a few studies have systematically evaluated fluoroscopy data of electrophysiological and device implantation procedures. Aims of this study were to quantify ionizing radiation exposure for electrophysiological/device implantation procedures in a large series of patients and to analyze the x-ray exposure trend over years and radiation exposure in patients undergoing atrial fibrillation ablation considering different technical aspects. Methods and Results--We performed a retrospective analysis of all electrophysiological/device implantation procedures performed during the past 7 years in a modern, large-volume laboratory. We reported complete fluoroscopy data on 8150 electrophysiological/device implantation procedures (6095 electrophysiological and 2055 device implantation procedures); for each type of procedure, effective dose and lifetime attributable risk of cancer incidence and mortality were calculated. Over the 7-year period, we observed a significant trend reduction in fluoroscopy time, dose area product, and effective dose for all electrophysiological procedures (P < 0.001) and a not statistically significant trend reduction for device implantation procedures. Analyzing 2416 atrial fibrillation ablations, we observed a significant variability of fluoroscopy time, dose area product and effective dose among 7 different experienced operators (P < 0.0001) and a significant reduction of fluoroscopy use over time (P < 0.0001) for all of them. Considering atrial fibrillation ablation techniques, fluoroscopy time was not different (P = 0.74) for radiofrequency catheter ablation in comparison with cryoablation, though cryoablation was still associated with higher dose area product and effective dose values (P < 0.001). Conclusions--Electrophysiological procedures involve a nonnegligible x-ray use, leading to an increased risk of malignancy. Awareness of radiation-related risk, together with technological advances, can successfully optimize fluoroscopy use.
Atrial fibrillation; Catheter ablation; X-ray; Cardiology and Cardiovascular Medicine
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
giu-2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
JAHA.117.008233.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 527.46 kB
Formato Adobe PDF
527.46 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/585794
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 33
social impact