Background: The introduction of a camera-based dose-reduction strategy in myocardial perfusion imaging (MPI) clinical setting entails the definition of objective and reproducible criteria for establishing the amount of activity to be injected. Aim: The aim is to evaluate the impact of count statistics on the estimation of summed-scores (SS), end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF). Methods: Data rest/stress ECG-gated SPECT (2-day protocol and 8 MBq·kg−1) were acquired with Bright View gamma camera and Astonish algorithm for 40 normal-weight and 40 overweight patients. Assuming that count statistics of shorter acquisition time may simulate that of lower injected activity, three simultaneous scans (full-time, half-time, and quarter-time scans) were started at the same time but with different acquisition time/projection (30, 15 and 8 seconds). Results: A significant difference between SS values of half-time and quarter-time stress scans was found for overweight group (P = .006). Post hoc test showed significant differences for ESV (P < .05), EDV (P < .01) and EF (P < .05) between half-time and quarter-time scans for both patient groups. Conclusions: The reduction of the count-statistics to a quarter of the MPI reference influenced negatively the quantification in overweight patients. The decrease of radiopharmaceutical activity to 25% of the reference seems practicable for normal-weight patients, while it is more appropriate an activity reduction limited to 50% for overweight and obese patients.
Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients / M. Lecchi, I. Martinelli, O. Zoccarato, C. Maioli, G. Lucignani, A. Del Sole. - In: JOURNAL OF NUCLEAR CARDIOLOGY. - ISSN 1071-3581. - (2016), pp. 1-12. [Epub ahead of print] [10.1007/s12350-015-0382-2]
Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients
M. LecchiPrimo
;C. Maioli;G. Lucignani
;A. Del SoleUltimo
2016
Abstract
Background: The introduction of a camera-based dose-reduction strategy in myocardial perfusion imaging (MPI) clinical setting entails the definition of objective and reproducible criteria for establishing the amount of activity to be injected. Aim: The aim is to evaluate the impact of count statistics on the estimation of summed-scores (SS), end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF). Methods: Data rest/stress ECG-gated SPECT (2-day protocol and 8 MBq·kg−1) were acquired with Bright View gamma camera and Astonish algorithm for 40 normal-weight and 40 overweight patients. Assuming that count statistics of shorter acquisition time may simulate that of lower injected activity, three simultaneous scans (full-time, half-time, and quarter-time scans) were started at the same time but with different acquisition time/projection (30, 15 and 8 seconds). Results: A significant difference between SS values of half-time and quarter-time stress scans was found for overweight group (P = .006). Post hoc test showed significant differences for ESV (P < .05), EDV (P < .01) and EF (P < .05) between half-time and quarter-time scans for both patient groups. Conclusions: The reduction of the count-statistics to a quarter of the MPI reference influenced negatively the quantification in overweight patients. The decrease of radiopharmaceutical activity to 25% of the reference seems practicable for normal-weight patients, while it is more appropriate an activity reduction limited to 50% for overweight and obese patients.File | Dimensione | Formato | |
---|---|---|---|
Lecchi et al. - 2016 - Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in norma.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
2.31 MB
Formato
Adobe PDF
|
2.31 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.