A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at -0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H<inf>2</inf>O<inf>2</inf> as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0ngmL<sup>-1</sup> Ara h 1, a detection limit of 6.3ngmL<sup>-1</sup>, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.
Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1 / V..R. Montiel, S. Campuzano, A. Pellicanò, R.M. Torrente-Rodríguez, A.J. Reviejo, M.S. Cosio, J.M. Pingarrón. - In: ANALYTICA CHIMICA ACTA. - ISSN 0003-2670. - 880(2015 Apr 20), pp. 52-59. [10.1016/j.aca.2015.04.041]
Sensitive and selective magnetoimmunosensing platform for determination of the food allergen Ara h 1
A. Pellicanò;M.S. CosioPenultimo
;
2015
Abstract
A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at -0.20V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of HPubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.