This prospective study has been designed to compare the results of immediate and delayed loading of implant-retained mandibular overdentures after a 2-year follow-up. Twenty patients have been randomly divided into two groups. Group 1 patients (test group) received four ITI implants in the intraforaminal area of the mandible. Octa abutments were immediately screwed on implants; 2 days after surgery, the implants were rigidly connected with a U-shaped Dolder gold bar and loaded with an overdenture. Group 2 patients (control group) received, in the same area, the same type and number of implants, which were left to heal according to the standard protocol. At 3-4 months, Octa abutments were screwed on the implants and the same prosthetic procedure of the test group was applied. The minimum follow-up period lasted 2 years, with recall appointments at 2 weeks, 1, 3, 6 months, 1 year and every following year postoperatively, evaluating: MPI, MBI, PD, Periotest and radiographic peri-implant bone resorption. Success criteria according to Albrektsson et al. were used. Only one implant out of the 40 of group 2 failed, whereas none failed in group 1. No statistical difference of the clinical parameters evaluated was noticed in the two groups. Therefore, immediate loading of implants, if connected with a U-shaped bar, can provide the same results of the 'traditional' technique as far as osseointegration and short-term survival rates of implants are concerned. Moreover, this method significantly shortens the treatment period, thus increasing patient satisfaction.

Implant-retained mandibular overdentures with ITI implants / E. Romeo, M. Chiapasco, A. Lazza, P. Casentini, M. Ghisolfi, M. Iorio, G. Vogel. - In: CLINICAL ORAL IMPLANTS RESEARCH. - ISSN 0905-7161. - 13:5(2002 Oct), pp. 495-501-501. [10.1034/j.1600-0501.2002.130508.x]

Implant-retained mandibular overdentures with ITI implants

E. Romeo
Primo
;
M. Chiapasco
Secondo
;
M. Ghisolfi;G. Vogel
Ultimo
2002

Abstract

This prospective study has been designed to compare the results of immediate and delayed loading of implant-retained mandibular overdentures after a 2-year follow-up. Twenty patients have been randomly divided into two groups. Group 1 patients (test group) received four ITI implants in the intraforaminal area of the mandible. Octa abutments were immediately screwed on implants; 2 days after surgery, the implants were rigidly connected with a U-shaped Dolder gold bar and loaded with an overdenture. Group 2 patients (control group) received, in the same area, the same type and number of implants, which were left to heal according to the standard protocol. At 3-4 months, Octa abutments were screwed on the implants and the same prosthetic procedure of the test group was applied. The minimum follow-up period lasted 2 years, with recall appointments at 2 weeks, 1, 3, 6 months, 1 year and every following year postoperatively, evaluating: MPI, MBI, PD, Periotest and radiographic peri-implant bone resorption. Success criteria according to Albrektsson et al. were used. Only one implant out of the 40 of group 2 failed, whereas none failed in group 1. No statistical difference of the clinical parameters evaluated was noticed in the two groups. Therefore, immediate loading of implants, if connected with a U-shaped bar, can provide the same results of the 'traditional' technique as far as osseointegration and short-term survival rates of implants are concerned. Moreover, this method significantly shortens the treatment period, thus increasing patient satisfaction.
Humans; Periodontal Pocket; Dental Restoration Failure; Aged; Weight-Bearing; Gingival Hemorrhage; Mandible; Dental Implants; Adult; Treatment Outcome; Dental Prosthesis, Implant-Supported; Osseointegration; Dental Plaque Index; Time Factors; Male; Survival Analysis; Denture, Overlay; Bone Resorption; Dental Abutments; Wound Healing; Alveolar Bone Loss; Denture, Complete, Lower; Prospective Studies; Follow-Up Studies; Middle Aged; Jaw, Edentulous; Statistics as Topic; Female; Statistics, Nonparametric
Settore MED/28 - Malattie Odontostomatologiche
ott-2002
Article (author)
File in questo prodotto:
File Dimensione Formato  
COIR 2002 overdenture ITI.pdf

accesso solo dalla rete interna

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 199.82 kB
Formato Adobe PDF
199.82 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/181521
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 129
  • ???jsp.display-item.citation.isi??? 117
social impact