Milking machine cleaning and microbiological quality of milk - Cleaning and maintenance of milking equipment is essential in order to obtain high quality milk. Many are the critical points of milking machine cleaning: water temperature, quantity and type of detergent and water turbulence. A total of 22 farms were visited three times in order to monitor milking machine cleaning using electronic flow meters (Lactocorder®). Cleaning process can be divided in three phases: pre-rinse, detergent phase and post-rinse. In our study the duration of detergent phase was 17.4±5.80 min, electrical conductivity of the detergent solution was 4.06±1.84 mS/cm and turbulence was 25.2±13.9 %. Maximum temperature detergent solution was on average 34.6±9.05°C, lower than the International guideline (43-77°C). The results underlines that farms using low water temperature (<35°C) had higher standard plate count in bulk tank milk than the others (4.12 log10/CFU vs 3.93 log10/CFU; P<0.05). Detergent phase duration had interesting effects on milking machine hygiene and bacterial quality of milk: 10 to 15 min seems to be the best time to reduce standard plate count in milk and standard plate count, thermoduric and psychrotrophic bacteria on milking equipment.

Lavaggio dell’impianto di mungitura e qualita’ microbiologica del latte / M. Zucali, L. Bava, M. Brasca, L. Vanoni, A. Tamburini, A. Sandrucci. - In: SCIENZA E TECNICA LATTIERO-CASEARIA. - ISSN 0390-6361. - 62:4(2011), pp. 251-256.

Lavaggio dell’impianto di mungitura e qualita’ microbiologica del latte

M. Zucali
Primo
;
L. Bava
Secondo
;
A. Tamburini
Penultimo
;
A. Sandrucci
Ultimo
2011

Abstract

Milking machine cleaning and microbiological quality of milk - Cleaning and maintenance of milking equipment is essential in order to obtain high quality milk. Many are the critical points of milking machine cleaning: water temperature, quantity and type of detergent and water turbulence. A total of 22 farms were visited three times in order to monitor milking machine cleaning using electronic flow meters (Lactocorder®). Cleaning process can be divided in three phases: pre-rinse, detergent phase and post-rinse. In our study the duration of detergent phase was 17.4±5.80 min, electrical conductivity of the detergent solution was 4.06±1.84 mS/cm and turbulence was 25.2±13.9 %. Maximum temperature detergent solution was on average 34.6±9.05°C, lower than the International guideline (43-77°C). The results underlines that farms using low water temperature (<35°C) had higher standard plate count in bulk tank milk than the others (4.12 log10/CFU vs 3.93 log10/CFU; P<0.05). Detergent phase duration had interesting effects on milking machine hygiene and bacterial quality of milk: 10 to 15 min seems to be the best time to reduce standard plate count in milk and standard plate count, thermoduric and psychrotrophic bacteria on milking equipment.
latte ; impianto di mungitura ; lavaggio
Settore AGR/19 - Zootecnica Speciale
2011
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/170366
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact