Introduction: the new fully automated HPLC ion-exchange system ADAMS A1c HA-8190V analyzer, developed by ARKRAY Inc., running in two different modes (Variant and Fast) has been evaluated. Methods: reproducibility was evaluated according to the EP-15A3 standard. Method comparison was performed on 122 fresh blood samples, according to the EP-9 standard. The system was compared to 3 other HPLC analyzers, based on ion-exchange (Tosoh G11 and Bio-Rad D-100) and boronate affinity chromatography (Trinity Biotech Premier Hb9210). Usability was evaluated by using to a score evaluation system. Results: reproducibility proved to be very good at normal and high HbA1c concentration, with total CVs always <0.7 %, when HbA1c was expressed in mmol/mol as well as in % units. The HA-8190V system was well correlated to the other HPLC analyzers, with a mean bias not clinically relevant. Finally, the usability of the system was evaluated and proved to be well acceptable. Conclusions: the ARKRAY HA-8190 V system was found to be a reliable and suitable method for routine HbA1c measurement in clinical chemistry laboratories.
Performance evaluation of Arkray HA-8190V system for measuring glycated hemoglobin / R. Paleari, F. Ceriotti, A. Mosca. - In: BIOCHIMICA CLINICA. - ISSN 0393-0564. - 46:1(2022), pp. 68-73. [10.19186/BC_2021.069]
Performance evaluation of Arkray HA-8190V system for measuring glycated hemoglobin
R. PaleariPrimo
;A. Mosca
Ultimo
2022
Abstract
Introduction: the new fully automated HPLC ion-exchange system ADAMS A1c HA-8190V analyzer, developed by ARKRAY Inc., running in two different modes (Variant and Fast) has been evaluated. Methods: reproducibility was evaluated according to the EP-15A3 standard. Method comparison was performed on 122 fresh blood samples, according to the EP-9 standard. The system was compared to 3 other HPLC analyzers, based on ion-exchange (Tosoh G11 and Bio-Rad D-100) and boronate affinity chromatography (Trinity Biotech Premier Hb9210). Usability was evaluated by using to a score evaluation system. Results: reproducibility proved to be very good at normal and high HbA1c concentration, with total CVs always <0.7 %, when HbA1c was expressed in mmol/mol as well as in % units. The HA-8190V system was well correlated to the other HPLC analyzers, with a mean bias not clinically relevant. Finally, the usability of the system was evaluated and proved to be well acceptable. Conclusions: the ARKRAY HA-8190 V system was found to be a reliable and suitable method for routine HbA1c measurement in clinical chemistry laboratories.File | Dimensione | Formato | |
---|---|---|---|
B_30_2022_Valutazione Arkray.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
2.73 MB
Formato
Adobe PDF
|
2.73 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.