COVID-19 containment measures hampered population cardiorespiratory fitness (which can be quantified as peak oxygen consumption (.VO2peak)) and the possibility to assess it using laboratory-based techniques. Although it is useful to ascertain the VO.2peak recovery after lockdowns, the community and most scientific institutions were unable to evaluate it. Wearable devices may pro-vide the opportunity to estimate cardiorespiratory fitness outside of the laboratory, without breaking self-isolation; herein, we explore the feasibility of this approach. Fifteen healthy participants were tested every 2 weeks for 10 weeks during a reduction of containment measures after a strict lockdown. Physical activity levels were measured using the International Physical Activity Questionnaire-Short. Form (IPAQ-SF). VO2peak was estimated through a previously validated test based on the speed of a 60 m sprint run, the baseline-to-peak heart rate (HR) variation, and the velocity of HR decay after the sprint, and measured through a wearable HR monitor. Participants increased physical activity from the end of lockdown (1833 [917–2594] MET-min/week; median [1st quartile–3rd quartile]) until the end of follow-up (2730 [1325–3380] MET-min/week). The estimated VO.2peak increased by 0.24 ± 0.19 mL/(min*kg*week) (regression coefficient ± standard error). Based on previous knowledge on the impact of inactivity on VO.2peak, our study indicates that a 10-week period of reducing the stringency of containment measures may not be sufficient to counteract the detrimental effects of the preceding lockdown.

From the Lab to Real Life: Monitoring Cardiorespiratory Fitness during the COVID-19 Pandemic through Wearable Devices. An Exploratory Longitudinal Study on Healthy Participants / F. Luciano, V. Cenacchi, L. Ruggiero, G. Pavei. - In: HEALTHCARE. - ISSN 2227-9032. - 10:4(2022 Apr), pp. 634.1-634.7. [10.3390/healthcare10040634]

From the Lab to Real Life: Monitoring Cardiorespiratory Fitness during the COVID-19 Pandemic through Wearable Devices. An Exploratory Longitudinal Study on Healthy Participants

F. Luciano
Primo
;
L. Ruggiero
Penultimo
;
G. Pavei
Ultimo
2022

Abstract

COVID-19 containment measures hampered population cardiorespiratory fitness (which can be quantified as peak oxygen consumption (.VO2peak)) and the possibility to assess it using laboratory-based techniques. Although it is useful to ascertain the VO.2peak recovery after lockdowns, the community and most scientific institutions were unable to evaluate it. Wearable devices may pro-vide the opportunity to estimate cardiorespiratory fitness outside of the laboratory, without breaking self-isolation; herein, we explore the feasibility of this approach. Fifteen healthy participants were tested every 2 weeks for 10 weeks during a reduction of containment measures after a strict lockdown. Physical activity levels were measured using the International Physical Activity Questionnaire-Short. Form (IPAQ-SF). VO2peak was estimated through a previously validated test based on the speed of a 60 m sprint run, the baseline-to-peak heart rate (HR) variation, and the velocity of HR decay after the sprint, and measured through a wearable HR monitor. Participants increased physical activity from the end of lockdown (1833 [917–2594] MET-min/week; median [1st quartile–3rd quartile]) until the end of follow-up (2730 [1325–3380] MET-min/week). The estimated VO.2peak increased by 0.24 ± 0.19 mL/(min*kg*week) (regression coefficient ± standard error). Based on previous knowledge on the impact of inactivity on VO.2peak, our study indicates that a 10-week period of reducing the stringency of containment measures may not be sufficient to counteract the detrimental effects of the preceding lockdown.
containment stringency; epidemic; lockdown; SARS-CoV-2; VO; 2max; VO; 2peak
Settore BIO/09 - Fisiologia
Settore M-EDF/01 - Metodi e Didattiche delle Attivita' Motorie
apr-2022
Article (author)
File in questo prodotto:
File Dimensione Formato  
healthcare-10-00634.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 629.62 kB
Formato Adobe PDF
629.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/925521
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact