Dentate nuclei (DNs) segmentation is helpful for assessing their potential involvement in neurological diseases. Once DNs have been segmented, it becomes possible to investigate whether DNs are microstructurally affected, through analysis of quantitative MRI parameters, such as those derived from diffusion weighted imaging (DWI). This study developed a fully automated segmentation method using the non-DWI (b0) images from a DWI dataset to obtain DN masks inherently registered with parameter maps. Three different automatic methods were applied to healthy subjects: registration to SUIT (a spatially unbiased atlas template of the cerebellum and brainstem), OPAL (Optimized Patch Match for Label fusion) and CNN (Convolutional Neural Network). DNs manual segmentation was considered the gold standard. Results show that SUIT results have a Dice Similarity Coefficient (DSC) of 0.4907±0.0793 between automatic and gold standard masks. Comparing OPAL (DSC = 0.7624±0.1786) and CNN (DSC = 0.8658±0.0255), showed that a better performance was obtained with CNN. OPAL and CNN were optimised on high spatial resolution data from the Human Connectome Project. The three methods were then used to segment DNs of subjects with Temporal Lobe Epilepsy (TLE) from a 3T MRI research study with DWI data acquired with a coarser resolution. In TLE, SUIT performed similarly, with a DSC = 0.4145±0.1023. OPAL performed worse than using HCP data with a DSC of 0.4522±0.1178. CNN was able to extract the DNs without need for retraining and with a DSC = 0.7368±0.0799. Statistical comparison of quantitative parameters from DWI analysis, as well as volumes, revealed altered and lateralised changes in TLE patients compared to healthy controls. The proposed CNN is a viable option for accurate extraction of DNs from b0 images of DWI data with different resolutions and acquired at different sites.

Automatic Segmentation of Dentate Nuclei for Microstructure Assessment: Example of Application to Temporal Lobe Epilepsy Patients / M. Gaviraghi, G. Savini, G. Castellazzi, F. Palesi, N. Rolandi, S. Sacco, A. Pichiecchio, V. Mariani, E. Tartara, L. Tassi, P. Vitali, E. D'Angelo, C.A.M.G. Wheeler-Kingshott (MATHEMATICS AND VISUALIZATION). - In: Computational Diffusion MRI / [a cura di] N. Gyori, J. Hutter, V. Nath, M. Palombo, M. Pizzolato, F. Zhang. - [s.l] : Springer Science and Business Media Deutschland GmbH, 2021. - ISBN 978-3-030-73017-8. - pp. 263-278 (( convegno International MICCAI tenutosi a Lima nel 2020 [10.1007/978-3-030-73018-5_21].

Automatic Segmentation of Dentate Nuclei for Microstructure Assessment: Example of Application to Temporal Lobe Epilepsy Patients

P. Vitali;
2021

Abstract

Dentate nuclei (DNs) segmentation is helpful for assessing their potential involvement in neurological diseases. Once DNs have been segmented, it becomes possible to investigate whether DNs are microstructurally affected, through analysis of quantitative MRI parameters, such as those derived from diffusion weighted imaging (DWI). This study developed a fully automated segmentation method using the non-DWI (b0) images from a DWI dataset to obtain DN masks inherently registered with parameter maps. Three different automatic methods were applied to healthy subjects: registration to SUIT (a spatially unbiased atlas template of the cerebellum and brainstem), OPAL (Optimized Patch Match for Label fusion) and CNN (Convolutional Neural Network). DNs manual segmentation was considered the gold standard. Results show that SUIT results have a Dice Similarity Coefficient (DSC) of 0.4907±0.0793 between automatic and gold standard masks. Comparing OPAL (DSC = 0.7624±0.1786) and CNN (DSC = 0.8658±0.0255), showed that a better performance was obtained with CNN. OPAL and CNN were optimised on high spatial resolution data from the Human Connectome Project. The three methods were then used to segment DNs of subjects with Temporal Lobe Epilepsy (TLE) from a 3T MRI research study with DWI data acquired with a coarser resolution. In TLE, SUIT performed similarly, with a DSC = 0.4145±0.1023. OPAL performed worse than using HCP data with a DSC of 0.4522±0.1178. CNN was able to extract the DNs without need for retraining and with a DSC = 0.7368±0.0799. Statistical comparison of quantitative parameters from DWI analysis, as well as volumes, revealed altered and lateralised changes in TLE patients compared to healthy controls. The proposed CNN is a viable option for accurate extraction of DNs from b0 images of DWI data with different resolutions and acquired at different sites.
Automatic segmentation; Deep learning; Dentate nuclei
Settore MED/37 - Neuroradiologia
2021
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
Gaviraghi2021_Chapter_AutomaticSegmentationOfDentate.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 366.43 kB
Formato Adobe PDF
366.43 kB Adobe PDF Visualizza/Apri