Background and aims: Congenital afibrinogenemia is a rare coagulation disorder resulting from a deficiency in fibrinogen. This study assessed the pharmacokinetics, surrogate efficacy and safety of FIB Grifols, a new human plasma-derived fibrinogen concentrate, to treat congenital afibrinogenemia. Methods: Eleven adult patients from a multinational, phase 1–2, prospective, open-label, single-arm, uncontrolled clinical study received a single infusion of FIB Grifols, 70 mg/kg bw. Fibrinogen pharmacokinetics (fibrinogen activity: Clauss method; antigen plasma concentrations: ELISA) and efficacy parameters were determined over 14 days after infusion. Efficacy endpoints were the mean change on plasma maximum clot firmness (MCF) on viscoelastic testing and coagulation tests 1-hour post-infusion, and correlation with fibrinogen levels throughout. Safety parameters were also assessed. Results: For the Clauss method, (mean [standard deviation]) baseline adjusted Cmax was 1.99 (0.40) g/L, reached 1.76 (1.00) h after infusion, and half-life was 76.94 (20.21) h. Using ELISA, Cmax after FIB Grifols infusion was 2.88 (0.86) mg/mL, with a tmax of 3.06 (2.24) h. Fibrinogen activity and antigen concentrations showed statistically significant correlation of 0.9120 (P < 0.001). Surrogate efficacy was demonstrated by a significant increase of 12.35 (3.85) mm in MCF. Prothrombin time, activated partial thromboplastin time and thrombin time, returned to normal ranges over time, indicating restoration of functionally active fibrinogen. There were no treatment-related adverse events, allergic reactions, serious adverse events, or discontinuations. Conclusions: The pharmacokinetic profile of functionally active FIB Grifols was established, hemostasis was restored, and FIB Grifols was safe and well tolerated in fibrinogen-deficient patients.

Pharmacokinetics, surrogate efficacy and safety evaluations of a new human plasma-derived fibrinogen concentrate (FIB Grifols) in adult patients with congenital afibrinogenemia / C.R. Ross, S. Subramanian, J. Navarro-Puerto, K. Subramanian, N.K. Kalappanavar, C.D. Khayat, S.S. Acharya, F. Peyvandi, K. Rucker, W. Liang, D. Vilardell, S. Trimm, J. Ayguasanosa. - In: THROMBOSIS RESEARCH. - ISSN 0049-3848. - 199(2021 Mar), pp. 110-118. [10.1016/j.thromres.2020.12.026]

Pharmacokinetics, surrogate efficacy and safety evaluations of a new human plasma-derived fibrinogen concentrate (FIB Grifols) in adult patients with congenital afibrinogenemia

F. Peyvandi;
2021

Abstract

Background and aims: Congenital afibrinogenemia is a rare coagulation disorder resulting from a deficiency in fibrinogen. This study assessed the pharmacokinetics, surrogate efficacy and safety of FIB Grifols, a new human plasma-derived fibrinogen concentrate, to treat congenital afibrinogenemia. Methods: Eleven adult patients from a multinational, phase 1–2, prospective, open-label, single-arm, uncontrolled clinical study received a single infusion of FIB Grifols, 70 mg/kg bw. Fibrinogen pharmacokinetics (fibrinogen activity: Clauss method; antigen plasma concentrations: ELISA) and efficacy parameters were determined over 14 days after infusion. Efficacy endpoints were the mean change on plasma maximum clot firmness (MCF) on viscoelastic testing and coagulation tests 1-hour post-infusion, and correlation with fibrinogen levels throughout. Safety parameters were also assessed. Results: For the Clauss method, (mean [standard deviation]) baseline adjusted Cmax was 1.99 (0.40) g/L, reached 1.76 (1.00) h after infusion, and half-life was 76.94 (20.21) h. Using ELISA, Cmax after FIB Grifols infusion was 2.88 (0.86) mg/mL, with a tmax of 3.06 (2.24) h. Fibrinogen activity and antigen concentrations showed statistically significant correlation of 0.9120 (P < 0.001). Surrogate efficacy was demonstrated by a significant increase of 12.35 (3.85) mm in MCF. Prothrombin time, activated partial thromboplastin time and thrombin time, returned to normal ranges over time, indicating restoration of functionally active fibrinogen. There were no treatment-related adverse events, allergic reactions, serious adverse events, or discontinuations. Conclusions: The pharmacokinetic profile of functionally active FIB Grifols was established, hemostasis was restored, and FIB Grifols was safe and well tolerated in fibrinogen-deficient patients.
Afibrinogenemia; Blood coagulation factor; Fibrinogen; Hemostasis; Pharmacokinetics; Adult; Blood Coagulation Tests; Fibrinogen; Humans; Prospective Studies; Afibrinogenemia; Hemostatics
Settore MED/09 - Medicina Interna
mar-2021
gen-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0049384821000037-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 500.29 kB
Formato Adobe PDF
500.29 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/905784
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact