Background: Low-volume preparations for colonoscopy have shown similar efficacy compared to high-volume ones in randomized controlled trials (RCT). However, most RCTs do not provide data about clinical outcomes including lesions detection rate. Moreover, real-life comparisons are lacking. Aim: To compare efficacy (both in terms of adequate bowel preparation and detection of colorectal lesions) and tolerability of a high-volume (HV: 4 L polyethylene glycol, PEG) and a low-volume (LV: 2 L PEG plus bisacodyl) bowel preparation in a real-life setting. Methods: Consecutive outpatients referred for colonoscopy were prospectively enrolled between 1 December 2014 and 31 December 2016. Patients could choose either LV or HV preparation, with a day-before schedule for morning colonoscopies and a split-dose for afternoon procedures. Adequate bowel preparation according to Boston Bowel Preparation Scale (BBPS), clinical outcomes including polyp detection rate (PDR), adenoma detection rate (ADR), advanced adenoma detection rate (AADR), sessile/serrated lesion detection rate (SDR) and cancer detection rate and self-reported tolerability of HV and LV were blindly assessed. Results: Total 2040 patients were enrolled and 1815 (mean age 60.6 years, 50.2% men) finally included. LV was chosen by 52% of patients (50.8% of men, 54.9% of women). Split-dose schedule was more common with HV (44.7% vs 38.2%, P = 0.005). High-definition scopes were used in 33.4% of patients, without difference in the two groups (P = 0.605). HV and LV preparations showed similar adequate bowel preparation rates (89.2% vs 86.6%, P = 0.098), also considering the two different schedules (HV split-dose 93.8% vs LV split-dose 93.6%, P = 1; HV day-before 85.5% vs LV day-before 82.3%, P = 0.182). Mean global BBPS score was higher for HV preparations (7.1 ± 1.7 vs 6.8 ± 1.6, P < 0.001). After adjustment for sex, age and indications for colonoscopy, HV preparation resulted higher in PDR [Odds ratio (OR) 1.32, 95%CI: 1.07-1.63, P = 0.011] and ADR (OR 1.29, 95%CI 1.02-1.63, P = 0.038) and comparable to LV in AADR (OR 1.51, 95%CI 0.97-2.35, P = 0.069), SDR and cancer detection rate. The use of standard-definition colonoscopes was associated to lower PDR (adjusted OR 1.59, 95%CI: 1.22-2.08, P < 0.001), ADR (adjusted OR 1.71, 95%CI: 1.26-2.30, P < 0.001) and AADR (adjusted OR 1.97, 95%CI: 1.09-3.56, P = 0.025) in patients receiving LV preparation. Mean Visual Analogue Scale tolerability scored equally (7, P = 0.627) but a ≥ 75% dose intake was more frequent with LV (94.6% vs 92.1%, P = 0.003). Conclusion: In a real-life setting, PEG-based low-volume preparation with bisacodyl showed similar efficacy and tolerability compared to standard HV preparation. However, with higher PDR and ADR, HV should still be considered as the reference standard for clinical trials and the preferred option in screening colonoscopy, especially when colonoscopy is performed with standard resolution imaging.
Efficacy and tolerability of high and low-volume bowel preparation compared : A real-life single-blinded large-population study / V. Occhipinti, P. Soriani, F. Bagolini, V. Milani, E. Rondonotti, M.L. Annunziata, F. Cavallaro, S. Vavassori, M. Vecchi, L. Pastorelli, G.E. Tontini. - In: WORLD JOURNAL OF GASTROINTESTINAL ENDOSCOPY. - ISSN 1948-5190. - 13:12(2021 Dec 16), pp. 659-672. [10.4253/wjge.v13.i12.659]
Efficacy and tolerability of high and low-volume bowel preparation compared : A real-life single-blinded large-population study
V. OcchipintiPrimo
;E. Rondonotti;F. Cavallaro;S. Vavassori;M. Vecchi;L. Pastorelli
Penultimo
;G.E. TontiniUltimo
2021
Abstract
Background: Low-volume preparations for colonoscopy have shown similar efficacy compared to high-volume ones in randomized controlled trials (RCT). However, most RCTs do not provide data about clinical outcomes including lesions detection rate. Moreover, real-life comparisons are lacking. Aim: To compare efficacy (both in terms of adequate bowel preparation and detection of colorectal lesions) and tolerability of a high-volume (HV: 4 L polyethylene glycol, PEG) and a low-volume (LV: 2 L PEG plus bisacodyl) bowel preparation in a real-life setting. Methods: Consecutive outpatients referred for colonoscopy were prospectively enrolled between 1 December 2014 and 31 December 2016. Patients could choose either LV or HV preparation, with a day-before schedule for morning colonoscopies and a split-dose for afternoon procedures. Adequate bowel preparation according to Boston Bowel Preparation Scale (BBPS), clinical outcomes including polyp detection rate (PDR), adenoma detection rate (ADR), advanced adenoma detection rate (AADR), sessile/serrated lesion detection rate (SDR) and cancer detection rate and self-reported tolerability of HV and LV were blindly assessed. Results: Total 2040 patients were enrolled and 1815 (mean age 60.6 years, 50.2% men) finally included. LV was chosen by 52% of patients (50.8% of men, 54.9% of women). Split-dose schedule was more common with HV (44.7% vs 38.2%, P = 0.005). High-definition scopes were used in 33.4% of patients, without difference in the two groups (P = 0.605). HV and LV preparations showed similar adequate bowel preparation rates (89.2% vs 86.6%, P = 0.098), also considering the two different schedules (HV split-dose 93.8% vs LV split-dose 93.6%, P = 1; HV day-before 85.5% vs LV day-before 82.3%, P = 0.182). Mean global BBPS score was higher for HV preparations (7.1 ± 1.7 vs 6.8 ± 1.6, P < 0.001). After adjustment for sex, age and indications for colonoscopy, HV preparation resulted higher in PDR [Odds ratio (OR) 1.32, 95%CI: 1.07-1.63, P = 0.011] and ADR (OR 1.29, 95%CI 1.02-1.63, P = 0.038) and comparable to LV in AADR (OR 1.51, 95%CI 0.97-2.35, P = 0.069), SDR and cancer detection rate. The use of standard-definition colonoscopes was associated to lower PDR (adjusted OR 1.59, 95%CI: 1.22-2.08, P < 0.001), ADR (adjusted OR 1.71, 95%CI: 1.26-2.30, P < 0.001) and AADR (adjusted OR 1.97, 95%CI: 1.09-3.56, P = 0.025) in patients receiving LV preparation. Mean Visual Analogue Scale tolerability scored equally (7, P = 0.627) but a ≥ 75% dose intake was more frequent with LV (94.6% vs 92.1%, P = 0.003). Conclusion: In a real-life setting, PEG-based low-volume preparation with bisacodyl showed similar efficacy and tolerability compared to standard HV preparation. However, with higher PDR and ADR, HV should still be considered as the reference standard for clinical trials and the preferred option in screening colonoscopy, especially when colonoscopy is performed with standard resolution imaging.File | Dimensione | Formato | |
---|---|---|---|
WJGE-13-659.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
788.72 kB
Formato
Adobe PDF
|
788.72 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.