Background: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum can not be collected in the majority of patients, and bronchoalveolar lavage (BAL), the most sensitive test, requires specific expertise. Laryngotracheal aspiration (LTA) is easy to perform and showed a similar accuracy to BAL for diagnosis of other pulmonary diseases, however it was not studied to diagnose SARS-COV-2 pneumonia. Objective: An observational cross-sectional study was performed to evaluate the negative predictive value of LTA in patients with suspected SARS-COV-2 pneumonia despite a negative NPS. Methods: In the EDs of two university hospitals, consecutive patients with suspected SARS-COV-2 pneumonia despite a negative NPS underwent LTA performed with a nasotracheal tube connected to a vacuum system. Final diagnosis based on all respiratory specimen tests (NPS, LTA and BAL) and hospital data was established by two reviewers and in case of discordance by a third reviewer. Results: 117 patients were enrolled. LTA was feasible in all patients and no patients experienced adverse events. Fifteen (12.7%) patients were diagnosed with community-acquired SARS-COV-2 pneumonia: 13 LTA positive and only 2 (1.7%) LTA negative. The negative predictive value of NPS and LTA was 87.3% (79.9% – 92.7%) and 98.1% (93.3.8%) respectively. Conclusions: LTA resulted feasible, safe and reduced false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative NPS.
Laryngotracheal aspiration test reduce the false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative nasopharyngeal swab / P. Nazerian, R.M. Sacco, M. Solbiati, E. Targetti, C. Marta, F. Blasi, G. Casazza, M.G. Colao, S. Tomassetti, S. Grifoni, G.M. Rossolini, G. Costantino. - In: EUROPEAN JOURNAL OF INTERNAL MEDICINE. - ISSN 0953-6205. - 91(2021), pp. 59-62. [10.1016/j.ejim.2021.06.019]
Laryngotracheal aspiration test reduce the false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative nasopharyngeal swab
R.M. Sacco;M. Solbiati;E. Targetti;F. Blasi;G. Casazza;G. CostantinoUltimo
2021
Abstract
Background: In the emergency department (ED) definitive diagnosis of SARS-COV-2 pneumonia is challenging as nasopharyngeal swab (NPS) can give false negative results. Strategies to reduce false negative rate of NPS have limitations. Serial NPSs (24–48 h from one another) are time-consuming, sputum can not be collected in the majority of patients, and bronchoalveolar lavage (BAL), the most sensitive test, requires specific expertise. Laryngotracheal aspiration (LTA) is easy to perform and showed a similar accuracy to BAL for diagnosis of other pulmonary diseases, however it was not studied to diagnose SARS-COV-2 pneumonia. Objective: An observational cross-sectional study was performed to evaluate the negative predictive value of LTA in patients with suspected SARS-COV-2 pneumonia despite a negative NPS. Methods: In the EDs of two university hospitals, consecutive patients with suspected SARS-COV-2 pneumonia despite a negative NPS underwent LTA performed with a nasotracheal tube connected to a vacuum system. Final diagnosis based on all respiratory specimen tests (NPS, LTA and BAL) and hospital data was established by two reviewers and in case of discordance by a third reviewer. Results: 117 patients were enrolled. LTA was feasible in all patients and no patients experienced adverse events. Fifteen (12.7%) patients were diagnosed with community-acquired SARS-COV-2 pneumonia: 13 LTA positive and only 2 (1.7%) LTA negative. The negative predictive value of NPS and LTA was 87.3% (79.9% – 92.7%) and 98.1% (93.3.8%) respectively. Conclusions: LTA resulted feasible, safe and reduced false negative rate in patients with suspected SARS-COV-2 pneumonia despite a negative NPS.File | Dimensione | Formato | |
---|---|---|---|
PIIS0953620521002302.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
349.55 kB
Formato
Adobe PDF
|
349.55 kB | Adobe PDF | Visualizza/Apri |