Background: During the COVID-19 pandemic, the use of protection masks is essential to reduce contagions. However, public opinion reports an associated subjective shortness of breath. We evaluated cardiorespiratory parameters at rest and during maximal exertion to highlight any differences with the use of protection masks. Methods: Twelve healthy subjects underwent three cardiopulmonary exercise tests: without wearing protection mask, with surgical and with FFP2 mask. Dyspnea was assessed by Borg Scale. Standard pulmonary function tests were also performed. Results: All the subjects (40.8±12.4 years; 6 males) completed the protocol with no adverse event. At spirometry, from no mask to surgical to FFP2, a progressive reduction of FEV1 and FVC was observed (3.94±0.91 l, 3.23±0.81 l, 2.94±0.98 l and 4.70±1.21 l, 3.77±1.02 l, 3.52±1.21 l, respectively, p<0.001). Rest ventilation, O2 uptake (V̇O2) and CO2 production (VCO2) were progressively lower with a reduction of respiratory rate. At peak exercise, subjects revealed a progressively higher Borg scale when wearing surgical and FFP2. Accordingly, at peak exercise, V̇O2 (31.0±23.4, 27.5±6.9, 28.2±8.8 ml/kg/min, p=0.001), ventilation (92±26, 76±22, 72±21 l, p=0.003), respiratory rate (42±8, 38±5, 37±4, p=0.04) and tidal volume (2.28±0.72, 2.05±0.60, 1.96±0.65 l, p=0.001) were gradually lower. We did not observed a significant difference in oxygen saturation. Conclusions: Protection masks are associated with significant but modest worsening of spirometry and cardiorespiratory parameters at rest and peak exercise. The effect is driven by a ventilation reduction due to an increased airflow resistance. However, since exercise ventilatory limitation is far from being reached, their use is safe even during maximal exercise, with a slight reduction in performance.

You can leave your mask on : Effects on cardiopulmonary parameters of different airway protection masks at rest and during maximal exercise / M. Mapelli, E. Salvioni, F. De Martino, I. Mattavelli, P. Gugliandolo, C. Vignati, S. Farina, P. Palermo, J. Campodonico, R. Maragna, G.V. LO RUSSO, A. Bonomi, S. Sciomer, P. Agostoni. - In: EUROPEAN RESPIRATORY JOURNAL. - ISSN 0903-1936. - 58:(2021), pp. 2004473.1-2004473.10. [10.1183/13993003.04473-2020]

You can leave your mask on : Effects on cardiopulmonary parameters of different airway protection masks at rest and during maximal exercise

M. Mapelli
Co-primo
;
E. Salvioni
Co-primo
;
C. Vignati;S. Farina;J.S. Campodonico;R. Maragna;G.V. LO RUSSO;P. Agostoni
Ultimo
2021

Abstract

Background: During the COVID-19 pandemic, the use of protection masks is essential to reduce contagions. However, public opinion reports an associated subjective shortness of breath. We evaluated cardiorespiratory parameters at rest and during maximal exertion to highlight any differences with the use of protection masks. Methods: Twelve healthy subjects underwent three cardiopulmonary exercise tests: without wearing protection mask, with surgical and with FFP2 mask. Dyspnea was assessed by Borg Scale. Standard pulmonary function tests were also performed. Results: All the subjects (40.8±12.4 years; 6 males) completed the protocol with no adverse event. At spirometry, from no mask to surgical to FFP2, a progressive reduction of FEV1 and FVC was observed (3.94±0.91 l, 3.23±0.81 l, 2.94±0.98 l and 4.70±1.21 l, 3.77±1.02 l, 3.52±1.21 l, respectively, p<0.001). Rest ventilation, O2 uptake (V̇O2) and CO2 production (VCO2) were progressively lower with a reduction of respiratory rate. At peak exercise, subjects revealed a progressively higher Borg scale when wearing surgical and FFP2. Accordingly, at peak exercise, V̇O2 (31.0±23.4, 27.5±6.9, 28.2±8.8 ml/kg/min, p=0.001), ventilation (92±26, 76±22, 72±21 l, p=0.003), respiratory rate (42±8, 38±5, 37±4, p=0.04) and tidal volume (2.28±0.72, 2.05±0.60, 1.96±0.65 l, p=0.001) were gradually lower. We did not observed a significant difference in oxygen saturation. Conclusions: Protection masks are associated with significant but modest worsening of spirometry and cardiorespiratory parameters at rest and peak exercise. The effect is driven by a ventilation reduction due to an increased airflow resistance. However, since exercise ventilatory limitation is far from being reached, their use is safe even during maximal exercise, with a slight reduction in performance.
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2021
7-mar-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
13993003.04473-2020.full.pdf

Open Access dal 08/03/2022

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/821409
Citazioni
  • ???jsp.display-item.citation.pmc??? 36
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 58
social impact