Limonta, E, Arienti, C, Rampichini, S, Venturelli, M, Cè, E, Veicsteinas, A, and Esposito, F. Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction. J Strength Cond Res 32(1): 230–236, 2018—The study was aimed at determining the acute effects of 2 types of occlusal splints on maximum isometric strength and fatigue of the elbow flexors muscles. The hypothesis was that splint-induced masticatory muscle repositioning might improve primary muscles recruitment by stretching masticatory muscles especially with the thicker splint. On 9 physically active volunteers with no temporomandibular joint and masticatory muscles disorders, we assessed maximum voluntary contraction (MVC) of the elbow flexors with diurnal (OSD, 1-mm thick) and sport (OSSP, 3-mm thick) splints, and without splint (control, Ctrl). On different days, participants performed 60 seconds of isometric contraction at 100% MVC (100`s) and 80% MVC contraction until exhaustion (80%exh) under OSD, OSSP, and Ctrl in random order. Time of force output within target (t-target), force distance from target (DF), and force coefficient of variation were calculated. Percentage of force decay (DFi-Fe) was determined during 100`s. From the electromyographic (EMG) signal, root mean square (EMG RMS) and mean frequency (EMG MF) were determined. Neuromuscular efficiency (NE) was calculated as the ratio between force and EMG RMS. MVC contraction and NE were significantly higher in OSSP and OSD than in Ctrl. During MVC, EMG MF was significantly lower in both splint conditions, and EMG RMS showed a non-statistical tendency to lower values under both splint conditions. During 80%exh, t-target was longer in OSD and OSSP (+7.8% and +5.2%, respectively) than in Ctrl. DFi-Fe was lower in OSSP than in Ctrl and OSD. These results support the hypothesis of a NE improvement of the elbow flexors possibly induced by acute, splint-induced masticatory muscles repositioning.

Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction / E. Limonta, C. Arienti, S. Rampichini, M. Venturelli, E. Ce', A. Veicsteinas, F. Esposito. - In: JOURNAL OF STRENGTH AND CONDITIONING RESEARCH. - ISSN 1064-8011. - 32:1(2018), pp. 230-236. [10.1519/JSC.0000000000002178]

Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction

E. Limonta;C. Arienti;S. Rampichini;M. Venturelli;E. Ce';A. Veicsteinas;F. Esposito
2018

Abstract

Limonta, E, Arienti, C, Rampichini, S, Venturelli, M, Cè, E, Veicsteinas, A, and Esposito, F. Effects of two different self-adapted occlusal splints on electromyographic and force parameters during elbow flexors isometric contraction. J Strength Cond Res 32(1): 230–236, 2018—The study was aimed at determining the acute effects of 2 types of occlusal splints on maximum isometric strength and fatigue of the elbow flexors muscles. The hypothesis was that splint-induced masticatory muscle repositioning might improve primary muscles recruitment by stretching masticatory muscles especially with the thicker splint. On 9 physically active volunteers with no temporomandibular joint and masticatory muscles disorders, we assessed maximum voluntary contraction (MVC) of the elbow flexors with diurnal (OSD, 1-mm thick) and sport (OSSP, 3-mm thick) splints, and without splint (control, Ctrl). On different days, participants performed 60 seconds of isometric contraction at 100% MVC (100`s) and 80% MVC contraction until exhaustion (80%exh) under OSD, OSSP, and Ctrl in random order. Time of force output within target (t-target), force distance from target (DF), and force coefficient of variation were calculated. Percentage of force decay (DFi-Fe) was determined during 100`s. From the electromyographic (EMG) signal, root mean square (EMG RMS) and mean frequency (EMG MF) were determined. Neuromuscular efficiency (NE) was calculated as the ratio between force and EMG RMS. MVC contraction and NE were significantly higher in OSSP and OSD than in Ctrl. During MVC, EMG MF was significantly lower in both splint conditions, and EMG RMS showed a non-statistical tendency to lower values under both splint conditions. During 80%exh, t-target was longer in OSD and OSSP (+7.8% and +5.2%, respectively) than in Ctrl. DFi-Fe was lower in OSSP than in Ctrl and OSD. These results support the hypothesis of a NE improvement of the elbow flexors possibly induced by acute, splint-induced masticatory muscles repositioning.
EMG; Endurance; Fatigue; Mouthguard; Strength; Adult; Elbow Joint; Electromyography; Humans; Isometric Contraction; Male; Masticatory Muscles; Muscle Strength; Muscle, Skeletal; Young Adult; Occlusal Splints
Settore M-EDF/02 - Metodi e Didattiche delle Attivita' Sportive
2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
Effects_of_Two_Different_Self_Adapted_Occlusal.29.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 347.65 kB
Formato Adobe PDF
347.65 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/810756
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact