Background: The national programs for the harmonization of hemoglobin (Hb)A1c measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA1c Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. Methods: Four method-comparison studies were performed in 2001–2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. Results: Significant differences were observed between the HbA1c results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA1c = 0.915(IFCC-HbA1c) + 2.15% (r2 = 0.998); JDS/JSCC-HbA1c = 0.927(IFCC-HbA1c) + 1.73% (r2 = 0.997); Swedish-HbA1c = 0.989(IFCC-HbA1c) + 0.88% (r2 = 0.996). Conclusion: There is a firm and reproducible link between the IFCC RM and DCM HbA1c values.

IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study / W. Hoelzel, C. Weykamp, J.O. Jeppsson, K. Miedema, J.R. Barr, I. Goodall, T. Hoshino, W.G. John, U. Kobold, R. Little, A. Mosca, P. Mauri, R. Paroni, F. Susanto, I. Takei, L. Thienpont, M. Umemoto, H.M. Wiedmeyer ; IFCC Working Group on HbA1c Standardizat. - In: CLINICAL CHEMISTRY. - ISSN 0009-9147. - 50:1(2004), pp. 166-174.

IFCC reference system for measurement of hemoglobin A1c in human blood and the national standardization schemes in the United States, Japan, and Sweden: a method-comparison study

A. Mosca;R. Paroni;
2004

Abstract

Background: The national programs for the harmonization of hemoglobin (Hb)A1c measurements in the US [National Glycohemoglobin Standardization Program (NGSP)], Japan [Japanese Diabetes Society (JDS)/Japanese Society of Clinical Chemistry (JSCC)], and Sweden are based on different designated comparison methods (DCMs). The future basis for international standardization will be the reference system developed by the IFCC Working Group on HbA1c Standardization. The aim of the present study was to determine the relationships between the IFCC Reference Method (RM) and the DCMs. Methods: Four method-comparison studies were performed in 2001–2003. In each study five to eight pooled blood samples were measured by 11 reference laboratories of the IFCC Network of Reference Laboratories, 9 Secondary Reference Laboratories of the NGSP, 3 reference laboratories of the JDS/JSCC program, and a Swedish reference laboratory. Regression equations were determined for the relationship between the IFCC RM and each of the DCMs. Results: Significant differences were observed between the HbA1c results of the IFCC RM and those of the DCMs. Significant differences were also demonstrated between the three DCMs. However, in all cases the relationship of the DCMs with the RM were linear. There were no statistically significant differences between the regression equations calculated for each of the four studies; therefore, the results could be combined. The relationship is described by the following regression equations: NGSP-HbA1c = 0.915(IFCC-HbA1c) + 2.15% (r2 = 0.998); JDS/JSCC-HbA1c = 0.927(IFCC-HbA1c) + 1.73% (r2 = 0.997); Swedish-HbA1c = 0.989(IFCC-HbA1c) + 0.88% (r2 = 0.996). Conclusion: There is a firm and reproducible link between the IFCC RM and DCM HbA1c values.
Settore BIO/10 - Biochimica
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2004
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/7979
Citazioni
  • ???jsp.display-item.citation.pmc??? 122
  • Scopus 603
  • ???jsp.display-item.citation.isi??? 527
social impact