Introduction: An optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes a novel workflow for one-step formation of the supra-implant emergence profile. Materials and Methods: Two randomized groups were selected. Ten control group participants received standard healing screws at the surgical stage. Ten individualized healing abutments were Computer aided Design/Computer aided Manufacturing (CAD/CAM)-fabricated out of polyether ether ketone (PEEK) restoration material in a fully digital workflow and seated at the surgical stage in the test group. The modified healing abutment shape was extracted from a virtual library. The standard triangulation language (STL) files of a premolar and a molar were obtained considering the coronal anatomy up to the cement-enamel junction (CEJ). After a healing period ranging from 1 to 3 months depending on the location of the surgical site, namely, mandible or maxilla, a digital impression was taken. The functional implant prosthodontics score (FIPS) and the numerical rating scale (NRS) of pain were recorded and compared. Results: The mean FIPS value for the test group was 9.1 ± 0.9 while the control group mean value was 7.1 ± 0.9. In the test group, pain assessment at crown placement presented a mean value of 0.5 ± 0.7. On the contrary, the control group showed a mean value of 5.5 ± 1.6. Conclusions: Patients in the test group showed higher FIPS values and lower NRS scores during the early phases compared to the control group.
Peri-implant soft tissue conditioning by means of customized healing abutment : a randomized controlled clinical trial / M. Beretta, P.P. Poli, S. Pieriboni, S. Tansella, M. Manfredini, M. Cicciù, C. Maiorana. - In: MATERIALS. - ISSN 1996-1944. - 12:18(2019), pp. 3041.1-3041.10. [10.3390/ma12183041]
Peri-implant soft tissue conditioning by means of customized healing abutment : a randomized controlled clinical trial
M. Beretta;P.P. Poli;S. Pieriboni;S. Tansella;M. Manfredini;C. Maiorana
2019
Abstract
Introduction: An optimal aesthetic implant restoration is a combination of a visually pleasing prosthesis and adequate surrounding peri-implant soft tissue architecture. This study describes a novel workflow for one-step formation of the supra-implant emergence profile. Materials and Methods: Two randomized groups were selected. Ten control group participants received standard healing screws at the surgical stage. Ten individualized healing abutments were Computer aided Design/Computer aided Manufacturing (CAD/CAM)-fabricated out of polyether ether ketone (PEEK) restoration material in a fully digital workflow and seated at the surgical stage in the test group. The modified healing abutment shape was extracted from a virtual library. The standard triangulation language (STL) files of a premolar and a molar were obtained considering the coronal anatomy up to the cement-enamel junction (CEJ). After a healing period ranging from 1 to 3 months depending on the location of the surgical site, namely, mandible or maxilla, a digital impression was taken. The functional implant prosthodontics score (FIPS) and the numerical rating scale (NRS) of pain were recorded and compared. Results: The mean FIPS value for the test group was 9.1 ± 0.9 while the control group mean value was 7.1 ± 0.9. In the test group, pain assessment at crown placement presented a mean value of 0.5 ± 0.7. On the contrary, the control group showed a mean value of 5.5 ± 1.6. Conclusions: Patients in the test group showed higher FIPS values and lower NRS scores during the early phases compared to the control group.File | Dimensione | Formato | |
---|---|---|---|
materials-12-03041.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
2.63 MB
Formato
Adobe PDF
|
2.63 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.