Objective: The aim of this prospective study was to compare the periodontal health and the microbiological changes via real-time polymerase chain reaction (PCR) in patients treated with fixed orthodontic appliances and Invisalign® system (Align Technology, Santa Clara, California). Materials and Methods: Seventy-seven patients were enrolled in this study and divided into three groups (Invisalign® group, fixed orthodontic appliances group and control group). Plaque index, probing depth, bleeding on probing were assessed. Total biofilm mass and periodontal pathogens were analyzed and detected via real-time PCR. All these data were analyzed at the T0 (beginning of the treatment) T1 (1-month) and T2 (3 months); and statistically compared using the Mann-Whitney test for independent groups. Results: After 1-month and after 3 months of treatment there was only one sample with periodontopathic anaerobes found in patient treated using fixed orthodontic appliances. The Invisalign® group showed better results in terms of periodontal health and total biofilm mass compared to the fixed orthodontic appliance group. A statistical significant difference (P < 0.05) at the T2 in the total biofilm mass was found between the two groups. Conclusion: Patients undergoing orthodontic treatment with the Invisalign® System show a superior periodontal health in the short-term when compared to patients in treatment with fixed orthodontic appliances. Invisalign® should be considered as a first treatment option in patients with risk of developing periodontal disease.
Periodontal health status in patients treated with the Invisalign® system and fixed orthodontic appliances: A 3 months clinical and microbiological evaluation / L. Levrini, A. Mangano, P. Montanari, S. Margherini, A. Caprioglio, M. Abbate Gian. - In: JOURNAL OF OROFACIAL ORTHOPEDICS. - ISSN 1615-6714. - 9:3(2015), pp. 404-410. [10.4103/1305-7456.163218]
Periodontal health status in patients treated with the Invisalign® system and fixed orthodontic appliances: A 3 months clinical and microbiological evaluation
A. Caprioglio;
2015
Abstract
Objective: The aim of this prospective study was to compare the periodontal health and the microbiological changes via real-time polymerase chain reaction (PCR) in patients treated with fixed orthodontic appliances and Invisalign® system (Align Technology, Santa Clara, California). Materials and Methods: Seventy-seven patients were enrolled in this study and divided into three groups (Invisalign® group, fixed orthodontic appliances group and control group). Plaque index, probing depth, bleeding on probing were assessed. Total biofilm mass and periodontal pathogens were analyzed and detected via real-time PCR. All these data were analyzed at the T0 (beginning of the treatment) T1 (1-month) and T2 (3 months); and statistically compared using the Mann-Whitney test for independent groups. Results: After 1-month and after 3 months of treatment there was only one sample with periodontopathic anaerobes found in patient treated using fixed orthodontic appliances. The Invisalign® group showed better results in terms of periodontal health and total biofilm mass compared to the fixed orthodontic appliance group. A statistical significant difference (P < 0.05) at the T2 in the total biofilm mass was found between the two groups. Conclusion: Patients undergoing orthodontic treatment with the Invisalign® System show a superior periodontal health in the short-term when compared to patients in treatment with fixed orthodontic appliances. Invisalign® should be considered as a first treatment option in patients with risk of developing periodontal disease.File | Dimensione | Formato | |
---|---|---|---|
01_2015_parod_invisa.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
1.55 MB
Formato
Adobe PDF
|
1.55 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.