PURPOSE: To examine interobserver variability between the radiation oncologist (RTO) and the radiation therapist (RTT) in delineating the tumor bed (TB) in early breast cancer (BC). METHODS: We retrospectively analyzed patients who received a radiotherapy boost to the TB. In a first group, the clinical target volume (CTV) for the boost was the surgical bed, defined by using surgical clips. In a second group, the CTV was defined by identifying a seroma cavity or a metallic find on the scar. These contours were compared in terms of volume, number of slices, and Dice similarity coefficient (DSC). RESULTS: Forty patients were assessed: 20 had surgical clips (group 1) while the other 20 had none (group 2). There was no difference in the number of slices contoured by the 2 operators for group 1, but a statistically significant difference emerged in the volumes: the RTT identified a TB that was a mean 45% smaller than the one identified by the RTO. Random differences were found between the 2 operators for group 2. The TBs delineated for this group were significantly larger (P<0.05) than those identified by the RTT for group 1. The mean Dice value between the RTO's and the RTT's TBs was 0.69±0.07 (range 0.53-0.81) for group 1 and 0.37±0.18 (range 0-0.58) for group 2 (P<0.05). CONCLUSIONS: This study showed that the use of clips coincided with less interoperator variability. With appropriate training, the RTT may play an important part in the multidisciplinary radiotherapy team.

Interobserver variability (between radiation oncologist and radiation therapist) in tumor bed contouring after breast-conserving surgery / E. La Rocca, V. Lici, T. Giandini, F. Bonfantini, S. Frasca, M. Dispinzieri, M. Gennaro, S. Di Cosimo, L. Lozza, E. Pignoli, R. Valdagni, M.C. De Santis. - In: TUMORI. - ISSN 0300-8916. - 105:3(2019 Jun 01), pp. 210-215. [10.1177/0300891619839288]

Interobserver variability (between radiation oncologist and radiation therapist) in tumor bed contouring after breast-conserving surgery

T. Giandini;F. Bonfantini;M. Dispinzieri;E. Pignoli;R. Valdagni;
2019

Abstract

PURPOSE: To examine interobserver variability between the radiation oncologist (RTO) and the radiation therapist (RTT) in delineating the tumor bed (TB) in early breast cancer (BC). METHODS: We retrospectively analyzed patients who received a radiotherapy boost to the TB. In a first group, the clinical target volume (CTV) for the boost was the surgical bed, defined by using surgical clips. In a second group, the CTV was defined by identifying a seroma cavity or a metallic find on the scar. These contours were compared in terms of volume, number of slices, and Dice similarity coefficient (DSC). RESULTS: Forty patients were assessed: 20 had surgical clips (group 1) while the other 20 had none (group 2). There was no difference in the number of slices contoured by the 2 operators for group 1, but a statistically significant difference emerged in the volumes: the RTT identified a TB that was a mean 45% smaller than the one identified by the RTO. Random differences were found between the 2 operators for group 2. The TBs delineated for this group were significantly larger (P<0.05) than those identified by the RTT for group 1. The mean Dice value between the RTO's and the RTT's TBs was 0.69±0.07 (range 0.53-0.81) for group 1 and 0.37±0.18 (range 0-0.58) for group 2 (P<0.05). CONCLUSIONS: This study showed that the use of clips coincided with less interoperator variability. With appropriate training, the RTT may play an important part in the multidisciplinary radiotherapy team.
Breast cancer; interobserver variability; surgical clips; tumor bed delineation; Aged; Breast Neoplasms; Female; Humans; Mastectomy, Segmental; Middle Aged; Observer Variation; Radiation Oncologists; Radiotherapy Planning, Computer-Assisted; Surgical Instruments; Tomography, X-Ray Computed; Tumor Burden
Settore MED/36 - Diagnostica per Immagini e Radioterapia
1-giu-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
0300891619839288.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 218.65 kB
Formato Adobe PDF
218.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/656974
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact