Purpose The development of new computer-assisted navigation technologies in total knee arthroplasty (TKA) has attracted great interest; however, the debate remains open as to the real reliability of these systems. We compared conventional TKA with last generation computer-navigated TKA to find out if navigation can reach better radiographic and clinical outcomes. Methods Twenty patients with tricompartmental knee osteoarthritis were prospectively selected for conventional TKA (n = 10) or last generation computer-navigated TKA (n = 10). Data regarding age, gender, operated side, and previous surgery were collected. All 20 patients received the same cemented posterior-stabilized TKA. The same surgical instrumentation, including alignment and cutting guides, was used for both the techniques. A single radiologist assessed mechanical alignment and tibial slope before and after surgery. A single orthopaedic surgeon performed clinical evaluation at 1 year after the surgery. Wilcoxon’s test was used to compare the outcomes of the two groups. Statistical significance was set at p < 0.05. Results No significant differences in mechanical axis or tibial slope was found between the two groups. The clinical outcome was equally good with both techniques. At a mean follow-up of 15.5 months (range, 13–25 months), all patients from both groups were generally satisfied with a full return to daily activities and without a significance difference between them. Conclusion Our data showed that clinical and radiological outcomes of TKA were not improved by the use of computer-assisted instruments, and that the elevated costs of the system are not warranted. Level of Evidence This is a Level II, randomized clinical trial.
Conventional versus smart wireless navigation in total knee replacement: Similar outcomes in a randomized prospective study / M. Denti, F. Soldati, F. Bartolucci, E. Morenghi, L. De Girolamo, P. Randelli. - In: JOINTS. - ISSN 2282-4324. - 6:2(2018), pp. 90-94. [10.1055/s-0038-1660813]
Conventional versus smart wireless navigation in total knee replacement: Similar outcomes in a randomized prospective study
E. Morenghi;L. De Girolamo;P. Randelli
2018
Abstract
Purpose The development of new computer-assisted navigation technologies in total knee arthroplasty (TKA) has attracted great interest; however, the debate remains open as to the real reliability of these systems. We compared conventional TKA with last generation computer-navigated TKA to find out if navigation can reach better radiographic and clinical outcomes. Methods Twenty patients with tricompartmental knee osteoarthritis were prospectively selected for conventional TKA (n = 10) or last generation computer-navigated TKA (n = 10). Data regarding age, gender, operated side, and previous surgery were collected. All 20 patients received the same cemented posterior-stabilized TKA. The same surgical instrumentation, including alignment and cutting guides, was used for both the techniques. A single radiologist assessed mechanical alignment and tibial slope before and after surgery. A single orthopaedic surgeon performed clinical evaluation at 1 year after the surgery. Wilcoxon’s test was used to compare the outcomes of the two groups. Statistical significance was set at p < 0.05. Results No significant differences in mechanical axis or tibial slope was found between the two groups. The clinical outcome was equally good with both techniques. At a mean follow-up of 15.5 months (range, 13–25 months), all patients from both groups were generally satisfied with a full return to daily activities and without a significance difference between them. Conclusion Our data showed that clinical and radiological outcomes of TKA were not improved by the use of computer-assisted instruments, and that the elevated costs of the system are not warranted. Level of Evidence This is a Level II, randomized clinical trial.File | Dimensione | Formato | |
---|---|---|---|
JOINTS-1700041.pdf
accesso riservato
Tipologia:
Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione
3.31 MB
Formato
Adobe PDF
|
3.31 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
10-1055-s-0038-1660813.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
221.84 kB
Formato
Adobe PDF
|
221.84 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.