A large body of evidence attests that quality programs developed around the analytical phase of the total testing process would only produce limited improvements, since the large majority of errors encountered in clinical laboratories still prevails within extra-analytical areas of testing, especially in manually intensive preanalytical processes. Most preanalytical errors result from system flaws and insufficient audit of the operators involved in specimen collection and handling responsibilities, leading to an unacceptable number of unsuitable specimens due to misidentification, in vitro hemolysis, clotting, inappropriate volume, wrong container or contamination from infusive routes. Detection and management of unsuitable samples are necessary to overcome this variability. The present document, issued by the Italian Inter-society SIBioC-SIMeL-CISMEL (Society of Clinical Biochemistry and Clinical Molecular Biology-Italian Society of Laboratory Medicine-Italian Committee for Standardization of Hematological and Laboratory Methods) Study Group on Extra-analytical Variability, reviews the major causes of unsuitable specimens in clinical laboratories, providing consensus recommendations for detection and management.

Recommendations for detection and management of unsuitable samples in clinical laboratories / G. Lippi, G. Banfi, M. Buttarello, F. Ceriotti, M. Daves, A. Dolci, M. Caputo, D. Giavarina, M. Montagnana, V. Miconi, B. Milanesi, A. Mosca, M. Morandini, G.L. Salvagno. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 45:6(2007), pp. 728-736.

Recommendations for detection and management of unsuitable samples in clinical laboratories

A. Dolci;A. Mosca;
2007

Abstract

A large body of evidence attests that quality programs developed around the analytical phase of the total testing process would only produce limited improvements, since the large majority of errors encountered in clinical laboratories still prevails within extra-analytical areas of testing, especially in manually intensive preanalytical processes. Most preanalytical errors result from system flaws and insufficient audit of the operators involved in specimen collection and handling responsibilities, leading to an unacceptable number of unsuitable specimens due to misidentification, in vitro hemolysis, clotting, inappropriate volume, wrong container or contamination from infusive routes. Detection and management of unsuitable samples are necessary to overcome this variability. The present document, issued by the Italian Inter-society SIBioC-SIMeL-CISMEL (Society of Clinical Biochemistry and Clinical Molecular Biology-Italian Society of Laboratory Medicine-Italian Committee for Standardization of Hematological and Laboratory Methods) Study Group on Extra-analytical Variability, reviews the major causes of unsuitable specimens in clinical laboratories, providing consensus recommendations for detection and management.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/43601
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 101
  • ???jsp.display-item.citation.isi??? 89
social impact