Background: Liver stiffness (LS) measured by transient elastography (TE) accurately predicts the severity of chronic liver diseases (CLD). Point quantification shear-wave elastography (pSWE) is a new technique incorporated into a conventional ultrasound system for measuring LS. We evaluated pSWE feasibility, reproducibility and diagnostic accuracy in consecutively recruited CLD patients who concomitantly underwent TE and liver biopsy. Aim: To evaluate pSWE feasibility, reproducibility and diagnostic accuracy in consecutively recruited CLD patients who concomitantly underwent TE and liver biopsy. Methods: Over 2 years 186 CLD patients (116 males, 132 viral hepatitis) consecutively underwent pSWE (10 valid measurements by ElastPQ) blindly performed by two raters. A further operator performed TE. Inter-observer agreement for pSWE was analysed by intraclass correlation coefficient (ICC) and correlated with histological liver fibrosis (METAVIR). Main determinants of pSWE were investigated by linear regression model. Results: Three hundred and seventy-two (100%) reliable measurements were obtained by pSWE and 184 by TE (99%). LS was 8.1 ± 4.5 kPa for pSWE with the first rater and 8.0 ± 4.2 kPa with the second one vs. 8.8 ± 3.6 kPa for TE. pSWE ICC was 0.89 (95% CI 0.85‒0.91), not influenced by age, sex, BMI, liver enzymes, liver aetiology. ICC increased over time with year 1 at 0.86 and 95% CI 0.81–0.90 vs. year 2 at 0.92 and 95% CI 0.87–0.95. Liver fibrosis was the only independent determinant of LS on pSWE. The AUROCs for diagnosing F ≥ 2, F ≥ 3 and F = 4 were 0.77, 0.85 and 0.88 for pSWE vs. 0.81, 0.88 and 0.94 for TE. After 1-year training they were 0.86, 0.94 and 0.91. Conclusion: Point quantification shear-wave elastography reliably and reproducibly evaluates liver stiffness, matching transient elastography for accuracy after a 1-year learning curve or 130 examinations.

Liver stiffness measurement reliability and main determinants of point shear-wave elastography in patients with chronic liver disease / M. Fraquelli, A. Baccarin, G. Casazza, C.B. Conti, M. Giunta, S. Massironi, F. Invernizzi, M.F. Donato, M. Maggioni, A. Aghemo, D. Conte, M. Colombo. - In: ALIMENTARY PHARMACOLOGY & THERAPEUTICS. - ISSN 0269-2813. - 44:4(2016), pp. 356-365. [10.1111/apt.13711]

Liver stiffness measurement reliability and main determinants of point shear-wave elastography in patients with chronic liver disease

A. Baccarin
Secondo
;
G. Casazza;C.B. Conti;M. Giunta;S. Massironi;F. Invernizzi;A. Aghemo;D. Conte
Penultimo
;
M. Colombo
Ultimo
2016

Abstract

Background: Liver stiffness (LS) measured by transient elastography (TE) accurately predicts the severity of chronic liver diseases (CLD). Point quantification shear-wave elastography (pSWE) is a new technique incorporated into a conventional ultrasound system for measuring LS. We evaluated pSWE feasibility, reproducibility and diagnostic accuracy in consecutively recruited CLD patients who concomitantly underwent TE and liver biopsy. Aim: To evaluate pSWE feasibility, reproducibility and diagnostic accuracy in consecutively recruited CLD patients who concomitantly underwent TE and liver biopsy. Methods: Over 2 years 186 CLD patients (116 males, 132 viral hepatitis) consecutively underwent pSWE (10 valid measurements by ElastPQ) blindly performed by two raters. A further operator performed TE. Inter-observer agreement for pSWE was analysed by intraclass correlation coefficient (ICC) and correlated with histological liver fibrosis (METAVIR). Main determinants of pSWE were investigated by linear regression model. Results: Three hundred and seventy-two (100%) reliable measurements were obtained by pSWE and 184 by TE (99%). LS was 8.1 ± 4.5 kPa for pSWE with the first rater and 8.0 ± 4.2 kPa with the second one vs. 8.8 ± 3.6 kPa for TE. pSWE ICC was 0.89 (95% CI 0.85‒0.91), not influenced by age, sex, BMI, liver enzymes, liver aetiology. ICC increased over time with year 1 at 0.86 and 95% CI 0.81–0.90 vs. year 2 at 0.92 and 95% CI 0.87–0.95. Liver fibrosis was the only independent determinant of LS on pSWE. The AUROCs for diagnosing F ≥ 2, F ≥ 3 and F = 4 were 0.77, 0.85 and 0.88 for pSWE vs. 0.81, 0.88 and 0.94 for TE. After 1-year training they were 0.86, 0.94 and 0.91. Conclusion: Point quantification shear-wave elastography reliably and reproducibly evaluates liver stiffness, matching transient elastography for accuracy after a 1-year learning curve or 130 examinations.
No
English
pharmacology (medical)
Settore MED/12 - Gastroenterologia
Articolo
Esperti anonimi
Pubblicazione scientifica
2016
Blackwell Publishing
44
4
356
365
10
Pubblicato
Periodico con rilevanza internazionale
scopus
crossref
pubmed
Aderisco
info:eu-repo/semantics/article
Liver stiffness measurement reliability and main determinants of point shear-wave elastography in patients with chronic liver disease / M. Fraquelli, A. Baccarin, G. Casazza, C.B. Conti, M. Giunta, S. Massironi, F. Invernizzi, M.F. Donato, M. Maggioni, A. Aghemo, D. Conte, M. Colombo. - In: ALIMENTARY PHARMACOLOGY & THERAPEUTICS. - ISSN 0269-2813. - 44:4(2016), pp. 356-365. [10.1111/apt.13711]
reserved
Prodotti della ricerca::01 - Articolo su periodico
12
262
Article (author)
no
M. Fraquelli, A. Baccarin, G. Casazza, C.B. Conti, M. Giunta, S. Massironi, F. Invernizzi, M.F. Donato, M. Maggioni, A. Aghemo, D. Conte, M. Colombo
File in questo prodotto:
File Dimensione Formato  
Fraquelli_AlimentaryPharmacologyTherapeutics_2016.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 337.86 kB
Formato Adobe PDF
337.86 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/431666
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 36
social impact