Purpose To compare the diagnostic performance of cone-beam CT (CBCT)-guided and CT fluoroscopy (fluoro-CT)-guided technique for transthoracic needle biopsy (TNB) of lung nodules. Methods The hospital records of 319 consecutive patients undergoing 324 TNBs of lung nodules in a single radiology unit in 2009-2013 were retrospectively evaluated. The newly introduced CBCT technology was used to biopsy 123 nodules; 201 nodules were biopsied by conventional fluoro-CT-guided technique. We assessed the performance of the two biopsy systems for diagnosis of malignancy and the radiation exposure. Results Nodules biopsied by CBCT-guided and by fluoro-CT-guided technique had similar characteristics: size, 20 +/- 6.5 mm (mean +/- standard deviation) vs. 20 +/- 6.8 mm (p = 0.845); depth from pleura, 15 +/- 15 mm vs. 15 +/- 16 mm (p = 0.595); malignant, 60 % vs. 66 % (p = 0.378). After a learning period, the newly introduced CBCT-guided biopsy system and the conventional fluoro-CT-guided system showed similar sensitivity (95 % and 92 %), specificity (100 % and 100 %), accuracy for diagnosis of malignancy (96 % and 94 %), and delivered non-significantly different median effective doses [11.1 mSv (95 % CI 8.9-16.0) vs. 14.5 mSv (95 % CI 9.5-18.1); p = 0.330]. Conclusion The CBCT-guided and fluoro-CT-guided systems for lung nodule biopsy are similar in terms of diagnostic performance and effective dose, and may be alternatively used to optimize the available technological resources.

Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules / N. Rotolo, C. Floridi, A. Imperatori, F. Fontana, A.M. Ierardi, M. Mangini, V. Arlant, G. De Marchi, R. Novario, L. Dominioni, C. Fugazzola, G. Carrafiello. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 26:2(2016), pp. 381-389. [10.1007/s00330-015-3861-6]

Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules

N. Rotolo
Primo
;
C. Floridi;G. Carrafiello
2016

Abstract

Purpose To compare the diagnostic performance of cone-beam CT (CBCT)-guided and CT fluoroscopy (fluoro-CT)-guided technique for transthoracic needle biopsy (TNB) of lung nodules. Methods The hospital records of 319 consecutive patients undergoing 324 TNBs of lung nodules in a single radiology unit in 2009-2013 were retrospectively evaluated. The newly introduced CBCT technology was used to biopsy 123 nodules; 201 nodules were biopsied by conventional fluoro-CT-guided technique. We assessed the performance of the two biopsy systems for diagnosis of malignancy and the radiation exposure. Results Nodules biopsied by CBCT-guided and by fluoro-CT-guided technique had similar characteristics: size, 20 +/- 6.5 mm (mean +/- standard deviation) vs. 20 +/- 6.8 mm (p = 0.845); depth from pleura, 15 +/- 15 mm vs. 15 +/- 16 mm (p = 0.595); malignant, 60 % vs. 66 % (p = 0.378). After a learning period, the newly introduced CBCT-guided biopsy system and the conventional fluoro-CT-guided system showed similar sensitivity (95 % and 92 %), specificity (100 % and 100 %), accuracy for diagnosis of malignancy (96 % and 94 %), and delivered non-significantly different median effective doses [11.1 mSv (95 % CI 8.9-16.0) vs. 14.5 mSv (95 % CI 9.5-18.1); p = 0.330]. Conclusion The CBCT-guided and fluoro-CT-guided systems for lung nodule biopsy are similar in terms of diagnostic performance and effective dose, and may be alternatively used to optimize the available technological resources.
Lung nodule biopsy; Transthoracic needle biopsy; C-arm cone-beam CT; CT fluoroscopy; Radiation dose
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2016
6-giu-2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs00330-015-3861-6.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.14 MB
Formato Adobe PDF
2.14 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/431537
Citazioni
  • ???jsp.display-item.citation.pmc??? 23
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 45
social impact