Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS Institutional Research Information System - AIR Archivio Istituzionale della Ricerca
First results are reported from a major new initiative of experiments, which focus on nuclear
structure studies at extreme isospin values by means of isomer spectroscopy. The experiments represent the
first part of the so-called stopped-beam campaign within the Rare ISotope INvestigations at GSI (Rising)
project. Time-correlated γ decays from individually identified nuclear species have been measured, allowing
the clean identification of isomeric decays in a wide range of exotic nuclei both at the proton drip-line and
in heavy, neutron-rich systems. An overview of the experimental technique will be given, together with the
performance of the new germanium detector array and future research plans for the collaboration.
Exciting isomers from the first stopped-beam RISING campaign / D. Rudolph, S. Pietri, Z. Podolyak, P. H. Regan, A. B. Garnsworthy, R. Hoischen, S. J. Steer, F. Becker, P. Bednarczyk, L. Caceres, P. Doornenbal, H. Geissel, J. Gerl, M. Gorska, J. Grebosz, A. Kelic, I. Kojouharov, N. Kurz, F. Montes, W. Prokopowicz, T. Saito, H. Schaffner, S. Tashenov, E. Werner Malento, H. J. Wollersheim, L.L. Andersson, L. Atanasova, D.L. Balabanski, M.A. Bentley, G. Benzoni, B. Blank, A. Blazhev, C. Brandau, J.R. Brown, A.M. Bruce, F. Camera, W.N. Catford, I.J. Cullen, Z. Dombradi, E. Estevez, C. Fahlander, W. Gelletly, A. Heinz, M. Hellstrom, G. Ilie, E. K. Johansson, J. Jolie, G.A. Jones, A. Jungclaus, M. Kmiecik, F. G. Kondev, T. Kurtukian Nieto, S. Lalkovski, Z. Liu, A. Maj, S. Myalski, M. Pfutzner, T. Shizuma, A. J. Simons, S. Schwertel, P.M. Walker, O. Wieland. - In: THE EUROPEAN PHYSICAL JOURNAL. SPECIAL TOPICS. - ISSN 1951-6355. - 150:1(2007), pp. 173-176.
Exciting isomers from the first stopped-beam RISING campaign
D. Rudolph;S. Pietri;Z. Podolyak;P. H. Regan;A. B. Garnsworthy;R. Hoischen;S. J. Steer;F. Becker;P. Bednarczyk;L. Caceres;P. Doornenbal;H. Geissel;J. Gerl;M. Gorska;J. Grebosz;A. Kelic;I. Kojouharov;N. Kurz;F. Montes;W. Prokopowicz;T. Saito;H. Schaffner;S. Tashenov;E. Werner Malento;H. J. Wollersheim;L. L. Andersson;L. Atanasova;D. L. Balabanski;M. A. Bentley;G. Benzoni;B. Blank;A. Blazhev;C. Brandau;J. R. Brown;A. M. Bruce;F. Camera;W. N. Catford;I. J. Cullen;Z. Dombradi;E. Estevez;C. Fahlander;W. Gelletly;A. Heinz;M. Hellstrom;G. Ilie;E. K. Johansson;J. Jolie;G. A. Jones;A. Jungclaus;M. Kmiecik;F. G. Kondev;T. Kurtukian Nieto;S. Lalkovski;Z. Liu;A. Maj;S. Myalski;M. Pfutzner;T. Shizuma;A. J. Simons;S. Schwertel;P. M. Walker;O. Wieland
2007
Abstract
First results are reported from a major new initiative of experiments, which focus on nuclear
structure studies at extreme isospin values by means of isomer spectroscopy. The experiments represent the
first part of the so-called stopped-beam campaign within the Rare ISotope INvestigations at GSI (Rising)
project. Time-correlated γ decays from individually identified nuclear species have been measured, allowing
the clean identification of isomeric decays in a wide range of exotic nuclei both at the proton drip-line and
in heavy, neutron-rich systems. An overview of the experimental technique will be given, together with the
performance of the new germanium detector array and future research plans for the collaboration.
Exciting isomers from the first stopped-beam RISING campaign / D. Rudolph, S. Pietri, Z. Podolyak, P. H. Regan, A. B. Garnsworthy, R. Hoischen, S. J. Steer, F. Becker, P. Bednarczyk, L. Caceres, P. Doornenbal, H. Geissel, J. Gerl, M. Gorska, J. Grebosz, A. Kelic, I. Kojouharov, N. Kurz, F. Montes, W. Prokopowicz, T. Saito, H. Schaffner, S. Tashenov, E. Werner Malento, H. J. Wollersheim, L.L. Andersson, L. Atanasova, D.L. Balabanski, M.A. Bentley, G. Benzoni, B. Blank, A. Blazhev, C. Brandau, J.R. Brown, A.M. Bruce, F. Camera, W.N. Catford, I.J. Cullen, Z. Dombradi, E. Estevez, C. Fahlander, W. Gelletly, A. Heinz, M. Hellstrom, G. Ilie, E. K. Johansson, J. Jolie, G.A. Jones, A. Jungclaus, M. Kmiecik, F. G. Kondev, T. Kurtukian Nieto, S. Lalkovski, Z. Liu, A. Maj, S. Myalski, M. Pfutzner, T. Shizuma, A. J. Simons, S. Schwertel, P.M. Walker, O. Wieland. - In: THE EUROPEAN PHYSICAL JOURNAL. SPECIAL TOPICS. - ISSN 1951-6355. - 150:1(2007), pp. 173-176.
none
Prodotti della ricerca::01 - Articolo su periodico
62
262
Article (author)
no
D. Rudolph, S. Pietri, Z. Podolyak, P. H. Regan, A. B. Garnsworthy, R. Hoischen, S. J. Steer, F. Becker, P. Bednarczyk, L. Caceres, P. Doornenbal, H. Geissel, J. Gerl, M. Gorska, J. Grebosz, A. Kelic, I. Kojouharov, N. Kurz, F. Montes, W. Prokopowicz, T. Saito, H. Schaffner, S. Tashenov, E. Werner Malento, H. J. Wollersheim, L.L. Andersson, L. Atanasova, D.L. Balabanski, M.A. Bentley, G. Benzoni, B. Blank, A. Blazhev, C. Brandau, J.R. Brown, A.M. Bruce, F. Camera, W.N. Catford, I.J. Cullen, Z. Dombradi, E. Estevez, C. Fahlander, W. Gelletly, A. Heinz, M. Hellstrom, G. Ilie, E. K. Johansson, J. Jolie, G.A. Jones, A. Jungclaus, M. Kmiecik, F. G. Kondev, T. Kurtukian Nieto, S. Lalkovski, Z. Liu, A. Maj, S. Myalski, M. Pfutzner, T. Shizuma, A. J. Simons, S. Schwertel, P.M. Walker, O. Wieland
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/41902
Citazioni
ND
9
8
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.