Recently a revolutionary technique for quantitative PCR determination was introduced in diagnostic laboratories. To determine the influence of technical variability on the reliability of the quantitative assay, it is crucial to use External Quality Assurance (EQA) programs. An EQA program was developed in Italy to check the analytical performance of real-time PCR procedures based on Taq-Mantrade mark probes. This article suggests a new statistical approach to discriminate, using a bivariate technique, laboratory performance that appears to be questionable, by separately considering the two main features of the standard curve: analytical sensitivity and efficiency. Furthermore, specific indexes to evaluate the impact of these two features on the determination of the initial number of molecules are given to help to improve the assay procedure.

Bivariate statistical approach to evaluate laboratory performance by analysis of standard curves in an External Quality Assurance program for quantitative assays based on real-time PCR with Taq-Man probes / Giuseppe Reina, Claudio Orlando, Paola Rebora, Federico Ambrogi, Claudia Casini Raggi, Paolo Verderio, Ettore Marubini. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 44:1(2006 Jan), pp. 18-22.

Bivariate statistical approach to evaluate laboratory performance by analysis of standard curves in an External Quality Assurance program for quantitative assays based on real-time PCR with Taq-Man probes

Giuseppe Reina;Paola Rebora;Federico Ambrogi;Ettore Marubini
2006

Abstract

Recently a revolutionary technique for quantitative PCR determination was introduced in diagnostic laboratories. To determine the influence of technical variability on the reliability of the quantitative assay, it is crucial to use External Quality Assurance (EQA) programs. An EQA program was developed in Italy to check the analytical performance of real-time PCR procedures based on Taq-Mantrade mark probes. This article suggests a new statistical approach to discriminate, using a bivariate technique, laboratory performance that appears to be questionable, by separately considering the two main features of the standard curve: analytical sensitivity and efficiency. Furthermore, specific indexes to evaluate the impact of these two features on the determination of the initial number of molecules are given to help to improve the assay procedure.
Bivariate analysis; EQA program; Real-time PCR; Standard curves
Settore MED/01 - Statistica Medica
gen-2006
http://www.atypon-link.com/doi/abs/10.1515/CCLM.2006.004
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/30566
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact