Purpose The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. Methods This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Results Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. Conclusions This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. Clinical relevance A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. Level of evidence II.
Does a thrombin-based topical haemostatic agent reduce blood loss and transfusion requirements after total knee revision surgery? A randomized, controlled trial / C.L. Romanò, L. Monti, N. Logoluso, D. Romanò, L. Drago. - In: KNEE SURGERY, SPORTS TRAUMATOLOGY, ARTHROSCOPY. - ISSN 0942-2056. - 23:11(2015 Nov), pp. 3337-3342. [10.1007/s00167-014-3153-8]
Does a thrombin-based topical haemostatic agent reduce blood loss and transfusion requirements after total knee revision surgery? A randomized, controlled trial
L. Monti;N. Logoluso;L. Drago
2015
Abstract
Purpose The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. Methods This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Results Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. Conclusions This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. Clinical relevance A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. Level of evidence II.File | Dimensione | Formato | |
---|---|---|---|
art%3A10.1007%2Fs00167-014-3153-8.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
195.96 kB
Formato
Adobe PDF
|
195.96 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Versione editoriale con paginazione.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
362.01 kB
Formato
Adobe PDF
|
362.01 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.