Ricotta cheese is a dairy product characterised by a short shelf life. The aim of this study was to monitor changes occurring during storage of packed industrial Ricotta cheese using a simple and fast method. Several samples of manufactured Ricotta cheese were monitored during storage at three different temperatures (3, 10 and 20°C). Spectral data were collected over the range 12000 to 4400 cm-1 using a FT-NIR spectrometer fitted with an optic fibre working in diffuse reflectance. Some chemical and rheological parameters were also measured. Principal Component Analysis (PCA) was applied as an exploratory chemometric technique to each one of the three sets of data (FT-NIR, chemical and rheological data), and a calibration model between the NIR data set and chemical and rheological indices was developed by means of a PLS1 regression. The PCA results, showed in all cases the influence of the storage temperature on the shelf life trend, and were able to identify a critical day of shelf life for each storage temperature.

A preliminary study of using the FT-NIR spectroscopy to monitor the shelf-life of packed industrial Ricotta cheese / N. Sinelli, S. Barzaghi, C. Giardina, T.M.P. Cattaneo. - In: JOURNAL OF NEAR INFRARED SPECTROSCOPY. - ISSN 0967-0335. - 13:5(2005), pp. 293-300.

A preliminary study of using the FT-NIR spectroscopy to monitor the shelf-life of packed industrial Ricotta cheese

N. Sinelli
Primo
;
2005

Abstract

Ricotta cheese is a dairy product characterised by a short shelf life. The aim of this study was to monitor changes occurring during storage of packed industrial Ricotta cheese using a simple and fast method. Several samples of manufactured Ricotta cheese were monitored during storage at three different temperatures (3, 10 and 20°C). Spectral data were collected over the range 12000 to 4400 cm-1 using a FT-NIR spectrometer fitted with an optic fibre working in diffuse reflectance. Some chemical and rheological parameters were also measured. Principal Component Analysis (PCA) was applied as an exploratory chemometric technique to each one of the three sets of data (FT-NIR, chemical and rheological data), and a calibration model between the NIR data set and chemical and rheological indices was developed by means of a PLS1 regression. The PCA results, showed in all cases the influence of the storage temperature on the shelf life trend, and were able to identify a critical day of shelf life for each storage temperature.
NIR spectroscopy; FT-NIR spectroscopy; chemometrics; shelf life; Ricotta cheese
2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/25649
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? ND
social impact