Glucose meters have improved considerably since they were first introduced in 1960, but many questions are being asked about their accuracy and reliability in certain clinical situations. These questions have arisen because of the widespread use of these meters into clinical areas they have not been designed for such as critical care. The lack of understanding by some health professionals on factors that affect glucose results, such as sample type, glucose test strip methodologic limitations, calibration to recognized reference methods, and interferences, leads to misleading results that may affect patient care. Much debate continues on the quality specifications for glucose meters. Because there is an extensive use of these meters in different clinical scenarios, the setting of quality specifications will remain a challenge for regulatory and professional organizations. In this article, we have attempted to collect and provide rele vant information addressing the limitations above. Pivotal to obtaining the best quality of results is education, parti cularly for diabetic patients monitoring their glucose. The International Federation of Clinical Chemistry and Laboratory Medicine through its Point-of-Care Testing Task Force and its Working Group on Glucose Point-of-Care Testing is actively working toward improving the quality of glucose results by improving education and working with the industry to improve strip performance and work toward the better standardization of strips.

Glucose meters : fit for clinical purpose / R. Tirimacco, G. Koumantakis, R. Erasmus, A. Mosca, S. Sandberg, I.D. Watson, B. Goldsmith, P. Gillery. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 51:5(2013 May), pp. 943-952. [10.1515/cclm-2013-0011]

Glucose meters : fit for clinical purpose

A. Mosca;
2013

Abstract

Glucose meters have improved considerably since they were first introduced in 1960, but many questions are being asked about their accuracy and reliability in certain clinical situations. These questions have arisen because of the widespread use of these meters into clinical areas they have not been designed for such as critical care. The lack of understanding by some health professionals on factors that affect glucose results, such as sample type, glucose test strip methodologic limitations, calibration to recognized reference methods, and interferences, leads to misleading results that may affect patient care. Much debate continues on the quality specifications for glucose meters. Because there is an extensive use of these meters in different clinical scenarios, the setting of quality specifications will remain a challenge for regulatory and professional organizations. In this article, we have attempted to collect and provide rele vant information addressing the limitations above. Pivotal to obtaining the best quality of results is education, parti cularly for diabetic patients monitoring their glucose. The International Federation of Clinical Chemistry and Laboratory Medicine through its Point-of-Care Testing Task Force and its Working Group on Glucose Point-of-Care Testing is actively working toward improving the quality of glucose results by improving education and working with the industry to improve strip performance and work toward the better standardization of strips.
Diabetes mellitus; Glucose meters; Point-ofcare testing; Quality specifications
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
mag-2013
Article (author)
File in questo prodotto:
File Dimensione Formato  
2013_glucsoe_meters_CCLM.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 300.17 kB
Formato Adobe PDF
300.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/226057
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 12
social impact