In this work metabolic studies based on proton nuclear activation (PNA) are described. For such kind of experiments a very high sensitivity in concentration determination of adequate tracers in biological tissues is needed and the contemporary use of more than one isotope of some element is often necessary. Moreover the use of radioactive tracers is normally forbidden in healthy persons. PNA is usually obtained inducing (p, xn) reactions on the target nuclei by means of a proton beam of adequate energy. The large power released by the charged particle beam in biological targets (dried serum samples) requires an efficient cooling system and imposes a limitation in the beam intensity. The special irradiation chamber built to irradiate 30 samples at a time is described. An account will be given of metabolic studies on Fe, Mo, and Te in man and/or animal. Some fundamental metabolic parameters are extracted by means of compartment analysis. Data on blood serum clearance constants and relative intestinal absorption coefficients are discussed.

Use of cyclotron for trace element analysis in biological samples and related metabolism studies / N. Molho, M.C. Cantone, D. De Bartolo, G. Gambarini, A. Giussani, L. Pirola, C. Hansen, P. Roth, E. Werner. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - 79:1/4(1993), pp. 560-563. [10.1016/0168-583X(93)95413-Y]

Use of cyclotron for trace element analysis in biological samples and related metabolism studies

M.C. Cantone
Secondo
;
G. Gambarini;L. Pirola;
1993

Abstract

In this work metabolic studies based on proton nuclear activation (PNA) are described. For such kind of experiments a very high sensitivity in concentration determination of adequate tracers in biological tissues is needed and the contemporary use of more than one isotope of some element is often necessary. Moreover the use of radioactive tracers is normally forbidden in healthy persons. PNA is usually obtained inducing (p, xn) reactions on the target nuclei by means of a proton beam of adequate energy. The large power released by the charged particle beam in biological targets (dried serum samples) requires an efficient cooling system and imposes a limitation in the beam intensity. The special irradiation chamber built to irradiate 30 samples at a time is described. An account will be given of metabolic studies on Fe, Mo, and Te in man and/or animal. Some fundamental metabolic parameters are extracted by means of compartment analysis. Data on blood serum clearance constants and relative intestinal absorption coefficients are discussed.
English
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
Articolo
Esperti anonimi
1993
Elsevier
79
1/4
560
563
4
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Use of cyclotron for trace element analysis in biological samples and related metabolism studies / N. Molho, M.C. Cantone, D. De Bartolo, G. Gambarini, A. Giussani, L. Pirola, C. Hansen, P. Roth, E. Werner. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION B, BEAM INTERACTIONS WITH MATERIALS AND ATOMS. - ISSN 0168-583X. - 79:1/4(1993), pp. 560-563. [10.1016/0168-583X(93)95413-Y]
none
Prodotti della ricerca::01 - Articolo su periodico
9
262
Article (author)
Periodico senza Impact Factor
N. Molho, M.C. Cantone, D. De Bartolo, G. Gambarini, A. Giussani, L. Pirola, C. Hansen, P. Roth, E. Werner
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/225390
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
  • OpenAlex ND
social impact