The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR).

High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis : in-stent restenosis assessment by low-dose MDCT / D. Andreini, G. Pontone, A.L. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 21:7(2011 Jul), pp. 1430-1438. [10.1007/s00330-011-2085-7]

High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis : in-stent restenosis assessment by low-dose MDCT

D. Andreini;G. Pontone;A.L. Bartorelli;S. Mushtaq;E. Bertella;S. Cortinovis;P. Agostoni;C. Fiorentini;
2011

Abstract

The accuracy of computed tomography (CT) for assessment of coronary stents is as yet unproven and radiation exposure has been a concern. The aim of our study is to compare radiation dose and diagnostic performance of CT with prospective ECG-triggering versus retrospective ECG-triggering for the detection of in-stent restenosis (ISR).
No
English
Computed tomography; Coronary arteries; Coronary stents; In-stent restenosis; Invasive coronary angiography; Radiation dose
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
Pubblicazione scientifica
lug-2011
21
7
1430
1438
9
Pubblicato
Periodico con rilevanza internazionale
Pubmed
Aderisco
info:eu-repo/semantics/article
High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis : in-stent restenosis assessment by low-dose MDCT / D. Andreini, G. Pontone, A.L. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - 21:7(2011 Jul), pp. 1430-1438. [10.1007/s00330-011-2085-7]
none
Prodotti della ricerca::01 - Articolo su periodico
13
262
Article (author)
Periodico con Impact Factor
D. Andreini, G. Pontone, A.L. Bartorelli, S. Mushtaq, D. Trabattoni, E. Bertella, S. Cortinovis, A. Annoni, A. Formenti, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/220725
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 21
social impact