To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2).

Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography / G. Pontone, D. Andreini, A.L. Bartorelli, E. Bertella, S. Mushtaq, C. Foti, A. Formenti, L. Chiappa, A. Annoni, S. Cortinovis, A. Baggiano, E. Conte, F. Bovis, F. Veglia, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: CLINICAL RADIOLOGY. - ISSN 0009-9260. - 67:3(2012 Mar), pp. 207-215.

Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography

G. Pontone;D. Andreini;A.L. Bartorelli;E. Bertella;S. Mushtaq;A. Formenti;L. Chiappa;A. Annoni;S. Cortinovis;A. Baggiano;E. Conte;F. Veglia;P. Agostoni;C. Fiorentini;
2012

Abstract

To compare the feasibility, accuracy, and effective radiation dose (ED) of multidetector computed tomography (MDCT) in the detection of coronary artery disease using a combined ED-saving strategy including prospective electrocardiogram (ECG) triggering with a short x-ray window and a body mass index (BMI)-adapted imaging protocol using adaptive statistical iterative reconstruction (ASIR; group 1), in comparison with a prospective ECG triggering strategy alone (group 2).
English
Sensitivity and Specificity ; Radiation Dosage ; Multidetector Computed Tomography ; Coronary Angiography ; Humans ; Algorithms ; Aged ; Body Mass Index ; Radiographic Image Interpretation, Computer-Assisted ; Feasibility Studies ; Electrocardiography ; Middle Aged ; Time Factors ; Coronary Artery Disease ; Female ; Male
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Esperti anonimi
mar-2012
Elsevier
67
3
207
215
9
Pubblicato
Periodico con rilevanza internazionale
Pubmed
info:eu-repo/semantics/article
Feasibility and diagnostic accuracy of a low radiation exposure protocol for prospective ECG-triggering coronary MDCT angiography / G. Pontone, D. Andreini, A.L. Bartorelli, E. Bertella, S. Mushtaq, C. Foti, A. Formenti, L. Chiappa, A. Annoni, S. Cortinovis, A. Baggiano, E. Conte, F. Bovis, F. Veglia, G. Ballerini, P. Agostoni, C. Fiorentini, M. Pepi. - In: CLINICAL RADIOLOGY. - ISSN 0009-9260. - 67:3(2012 Mar), pp. 207-215.
reserved
Prodotti della ricerca::01 - Articolo su periodico
18
262
Article (author)
si
G. Pontone, D. Andreini, A.L. Bartorelli, E. Bertella, S. Mushtaq, C. Foti, A. Formenti, L. Chiappa, A. Annoni, S. Cortinovis, A. Baggiano, E. Conte, ...espandi
File in questo prodotto:
File Dimensione Formato  
pontone1-s2.0-S0009926011003072-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 530.88 kB
Formato Adobe PDF
530.88 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/220650
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 23
  • OpenAlex 25
social impact