The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(B-11,n gamma)C-12 at E-beam=19.1 MeV, while gamma rays between 2 and 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%.Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation caused by n-capture in Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape analysis is discussed.

Response of AGATA segmented HPGe detectors to gamma rays up to 15.1MeV / F. Crespi, R. Avigo, F. Camera, S. Akkoyun, A. Ataç, D. Bazzacco, M. Bellato, G. Benzoni, N. Blasi, D. Bortolato, S. Bottoni, A. Bracco, S. Brambilla, B. Bruyneel, S. Ceruti, M. Ciemała, S. Coelli, J. Eberth, C. Fanin, E. Farnea, A. Gadea, A. Giaz, A. Gottardo, H. Hess, M. Kmiecik, S. Leoni, A. Maj, D. Mengoni, C. Michelagnoli, B. Million, D. Montanari, R. Nicolini, L. Pellegri, F. Recchia, P. Reiter, S. Riboldi, C. Ur, V. Vandone, J. Valiente-Dobon, O. Wieland, A. Wiens. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 705(2013 Mar 21), pp. 47-54. [10.1016/j.nima.2012.12.084]

Response of AGATA segmented HPGe detectors to gamma rays up to 15.1MeV

F. Crespi;R. Avigo;F. Camera;S. Bottoni;A. Bracco;S. Ceruti;A. Giaz;S. Leoni;R. Nicolini;S. Riboldi;V. Vandone;
2013

Abstract

The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(B-11,n gamma)C-12 at E-beam=19.1 MeV, while gamma rays between 2 and 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%.Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation caused by n-capture in Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape analysis is discussed.
English
AGATA; Gamma-ray spectroscopy; Gamma-ray tracking; HPGe detectors; Pulse-shape and gamma-ray tracking algorithms; Semiconductor detector performance and simulations
Settore FIS/04 - Fisica Nucleare e Subnucleare
Articolo
Esperti anonimi
21-mar-2013
705
47
54
Pubblicato
Periodico con rilevanza internazionale
CrossRef
info:eu-repo/semantics/article
Response of AGATA segmented HPGe detectors to gamma rays up to 15.1MeV / F. Crespi, R. Avigo, F. Camera, S. Akkoyun, A. Ataç, D. Bazzacco, M. Bellato, G. Benzoni, N. Blasi, D. Bortolato, S. Bottoni, A. Bracco, S. Brambilla, B. Bruyneel, S. Ceruti, M. Ciemała, S. Coelli, J. Eberth, C. Fanin, E. Farnea, A. Gadea, A. Giaz, A. Gottardo, H. Hess, M. Kmiecik, S. Leoni, A. Maj, D. Mengoni, C. Michelagnoli, B. Million, D. Montanari, R. Nicolini, L. Pellegri, F. Recchia, P. Reiter, S. Riboldi, C. Ur, V. Vandone, J. Valiente-Dobon, O. Wieland, A. Wiens. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 705(2013 Mar 21), pp. 47-54. [10.1016/j.nima.2012.12.084]
open
Prodotti della ricerca::01 - Articolo su periodico
41
262
Article (author)
no
F. Crespi, R. Avigo, F. Camera, S. Akkoyun, A. Ataç, D. Bazzacco, M. Bellato, G. Benzoni, N. Blasi, D. Bortolato, S. Bottoni, A. Bracco, S. Brambilla,...espandi
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0168900212016324-main.pdf

Open Access dal 07/11/2013

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 827.22 kB
Formato Adobe PDF
827.22 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/219626
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 21
  • OpenAlex ND
social impact