Background Subtrochanteric femoral non-unions in the setting of failed metalwork pose a challenging clinical problem. This study assessed the clinical outcome of patients treated according to the principles of the “Diamond” concept. Methods Between 2007 and 2011 all patients presented with a subtrochanteric atrophic aseptic non-union in the setting of metalwork failure (broken cephalomedullary reconstruction nail), and treated in a single tertiary referral unit were included to this study. The hypertrophic and the non-unions of pathologic fractures were excluded. The revision strategy was based on the “Diamond concept”; optimisation of the mechanical and the biological environment (implantation of growth factor (rhBMP-7), scaffold (RIA bone graft from contralateral femur) and concentrated mesenchymal stem cells (MSCs) harvested from the iliac crest). The minimum follow up was 26 months (16–48). Results Fourteen patients met the inclusion criteria. A specific sequence of metalwork failure was noted with initial breakage of the distal locking screws followed by nail breakage at the lag screw level. The intraoperative examination of the removed nails revealed no gross structural damage indicative of inappropriate drilling at the time of the initial intramedullary nailing. Varus mal-alignment was present in the majority of the cases, with an average of 5.2 degrees (0–11). The average time to distal locking screw failure was 4.4 months (2–8.5) and nail failure was 6.5 months (4–10). The time to union after the revision surgery was 6.8 months (5–12). Complications included two deaths in elderly patients (due to unrelated causes), one pulmonary embolism, one myocardial infarction, one below the knee deep vein thrombosis and one blade plate failure that required further revision with double plating and grafting. Conclusion Varus mal-alignment must be avoided in the initial stabilisation of subtrochanteric fractures. Distal locking screw failure is predictive of future fracture non-union and nail breakage. In the absence of sepsis, a single stage procedure based on the “Diamond concept” that simultaneously optimizes the mechanical and biological environment is a successful method for managing complex subtrochanteric atrophic non-unions with failed metalwork.

Subtrochanteric fracture non-unions with implant failure managed with the Diamond Concept / P.V. Giannoudis, M.A. Ahmad, G.V. Mineo, T.I. Tosounidis, N.K. Kanakiris. - In: INJURY. - ISSN 0020-1383. - 44:Suppl.1(2013 Jan), pp. S76-S81. [10.1016/S0020-1383(13)70017-2]

Subtrochanteric fracture non-unions with implant failure managed with the Diamond Concept

G.V. Mineo;
2013

Abstract

Background Subtrochanteric femoral non-unions in the setting of failed metalwork pose a challenging clinical problem. This study assessed the clinical outcome of patients treated according to the principles of the “Diamond” concept. Methods Between 2007 and 2011 all patients presented with a subtrochanteric atrophic aseptic non-union in the setting of metalwork failure (broken cephalomedullary reconstruction nail), and treated in a single tertiary referral unit were included to this study. The hypertrophic and the non-unions of pathologic fractures were excluded. The revision strategy was based on the “Diamond concept”; optimisation of the mechanical and the biological environment (implantation of growth factor (rhBMP-7), scaffold (RIA bone graft from contralateral femur) and concentrated mesenchymal stem cells (MSCs) harvested from the iliac crest). The minimum follow up was 26 months (16–48). Results Fourteen patients met the inclusion criteria. A specific sequence of metalwork failure was noted with initial breakage of the distal locking screws followed by nail breakage at the lag screw level. The intraoperative examination of the removed nails revealed no gross structural damage indicative of inappropriate drilling at the time of the initial intramedullary nailing. Varus mal-alignment was present in the majority of the cases, with an average of 5.2 degrees (0–11). The average time to distal locking screw failure was 4.4 months (2–8.5) and nail failure was 6.5 months (4–10). The time to union after the revision surgery was 6.8 months (5–12). Complications included two deaths in elderly patients (due to unrelated causes), one pulmonary embolism, one myocardial infarction, one below the knee deep vein thrombosis and one blade plate failure that required further revision with double plating and grafting. Conclusion Varus mal-alignment must be avoided in the initial stabilisation of subtrochanteric fractures. Distal locking screw failure is predictive of future fracture non-union and nail breakage. In the absence of sepsis, a single stage procedure based on the “Diamond concept” that simultaneously optimizes the mechanical and biological environment is a successful method for managing complex subtrochanteric atrophic non-unions with failed metalwork.
BMP-7; Diamond concept; RIA graft; Subtrochanteric non-union
Settore MED/33 - Malattie Apparato Locomotore
gen-2013
http://www.injuryjournal.com/article/S0020-1383(13)70017-2/pdf
Article (author)
File in questo prodotto:
File Dimensione Formato  
SUBTROCHANTERIC FRACTURES NONUNIONS INJURY GEN 2013.pdf

accesso solo dalla rete interna

Tipologia: Publisher's version/PDF
Dimensione 1.1 MB
Formato Adobe PDF
1.1 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/215471
Citazioni
  • ???jsp.display-item.citation.pmc??? 35
  • Scopus 112
  • ???jsp.display-item.citation.isi??? 95
social impact