The direct effect of the ethylene glycol on the quantitation of glycated haemoglobins by ion-exchange minicolumn chromatography, affinity chromatography and high performance liquid chromatography was investigated. No evident effect was found for ethylene glycol concentrations between 0.0 and 0.5 (volume fraction). The ethylene glycol-stabilised haemolysates were also analysed by HPLC: the elution profiles were similar to those of haemolysates fresly prepared from whole blood, and they remained unchanged, even after 18 months of storage at -20 degrees C. A preliminary inter-laboratory trial among 15 Italian laboratories was organized, using these ethylene glycol-stabilised haemolysates and, for comparison, a lyophilized commercial preparation. From the data obtained in this trial we confirmed the validity of using ethylene glycol-stabilized haemolysates as control materials, both for intra- and inter-laboratory standardization of glycated haemoglobin measurements.

Ethylene glycol-stabilized haemolysates for glycated haemoglobin assay. Further analytical investigations and applications to quality control programmes / A. Mosca, A. Carpinelli, P. A. Bonini. - In: JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY. - ISSN 0340-076X. - 25:7(1987 Jul), pp. 447-50-450.

Ethylene glycol-stabilized haemolysates for glycated haemoglobin assay. Further analytical investigations and applications to quality control programmes

A. Mosca
Primo
;
1987

Abstract

The direct effect of the ethylene glycol on the quantitation of glycated haemoglobins by ion-exchange minicolumn chromatography, affinity chromatography and high performance liquid chromatography was investigated. No evident effect was found for ethylene glycol concentrations between 0.0 and 0.5 (volume fraction). The ethylene glycol-stabilised haemolysates were also analysed by HPLC: the elution profiles were similar to those of haemolysates fresly prepared from whole blood, and they remained unchanged, even after 18 months of storage at -20 degrees C. A preliminary inter-laboratory trial among 15 Italian laboratories was organized, using these ethylene glycol-stabilised haemolysates and, for comparison, a lyophilized commercial preparation. From the data obtained in this trial we confirmed the validity of using ethylene glycol-stabilized haemolysates as control materials, both for intra- and inter-laboratory standardization of glycated haemoglobin measurements.
Chromatography, Affinity; Hemoglobin A, Glycosylated; Ethylene Glycols; Humans; Hemolysis; Chromatography, Ion Exchange; Quality Control
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
lug-1987
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/192371
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 5
  • ???jsp.display-item.citation.isi??? ND
social impact