Carrier ampholytes covering a pH range corresponding to, or narrower than, the span of the immobilized pH gradient (IPG) are a most suitable electrodic solution for IPGs. They are able to collect, and completely remove from the gel, much higher amounts of non-buffering ions that are solutions of acidic and basic amino acids. This makes it possible to directly run IPGs just after their polymerization, without the need of a washing step to remove catalysts and unreacted Immunobiline monomers. The same applies most advantageously when the gel formulation includes urea and/or detergents. Ions contributed by the sample solution are also prevented from casting high-conductivity ridges around the electrodes, without any need either of a dialysis step or of an increased slab size with pH plateaus. The migration of the sample proteins toward their equilibrium position is faster in the presence of carrier ampholytes. The effective concentrations of the latter are in the range 0.3-1%.

WHICH ELECTRODIC SOLUTIONS FOR IMMOBILIZED PH GRADIENTS / E. GIANAZZA, L. QUAGLIA, P. CACCIA, P. RIGHETTI. - In: JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS. - ISSN 0165-022X. - 12:4(1986), pp. 227-237. [10.1016/0165-022X(86)90111-9]

WHICH ELECTRODIC SOLUTIONS FOR IMMOBILIZED PH GRADIENTS

E. Gianazza
Primo
;
1986

Abstract

Carrier ampholytes covering a pH range corresponding to, or narrower than, the span of the immobilized pH gradient (IPG) are a most suitable electrodic solution for IPGs. They are able to collect, and completely remove from the gel, much higher amounts of non-buffering ions that are solutions of acidic and basic amino acids. This makes it possible to directly run IPGs just after their polymerization, without the need of a washing step to remove catalysts and unreacted Immunobiline monomers. The same applies most advantageously when the gel formulation includes urea and/or detergents. Ions contributed by the sample solution are also prevented from casting high-conductivity ridges around the electrodes, without any need either of a dialysis step or of an increased slab size with pH plateaus. The migration of the sample proteins toward their equilibrium position is faster in the presence of carrier ampholytes. The effective concentrations of the latter are in the range 0.3-1%.
carrier ampholytes; detergents; equivalent ionic conductivity at infinite dilution; IEF; immobilized pH gradients; IPG; isoelectric focusing; TEMED; tetramethyleneethylenediamine; urea; λ0
Settore BIO/10 - Biochimica
1986
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/177679
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 19
social impact