Background: The cerebrospinal fluid (CSF) biomarkers amyloid β (Aβ)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer's disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer's Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for Aβ, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Mölndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure Aβ-(1-42), P-tau(181P), and T-tau), and 5 used Meso Scale Discovery with the Aβ triplex (AβN-42, AβN-40, and AβN-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers.

The Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers / N. Mattsson, U. Andreasson, S. Persson, H. Arai, S.D. Batish, S. Bernardini, L. Bocchio-Chiavetto, M.A. Blankenstein, M.C. Carrillo, S. Chalbot, E. Coart, D. Chiasserini, N. Cutler, G. Dahlfors, S. Duller, A.M. Fagan, O. Forlenza, G.B. Frisoni, D. Galasko, D. Galimberti, H. Hampel, A. Handberg, M.T. Heneka, A.Z. Herskovits, S.K. Herukka, D.M. Holtzman, C. Humpel, B.T. Hyman, K. Iqbal, M. Jucker, S.A. Kaeser, E. Kaiser, E. Kapaki, D. Kidd, P. Klivenyi, C.S. Knudsen, M.P. Kummer, J. Lui, A. Lladó, P. Lewczuk, Q.X. Li, R. Martins, C. Masters, J. McAuliffe, M. Mercken, A. Moghekar, J.L. Molinuevo, T.J. Montine, W. Nowatzke, R. O'Brien, M. Otto, G.P. Paraskevas, L. Parnetti, R.C. Petersen, D. Prvulovic, H.P. de Reus, R.A. Rissman, E. Scarpini, A. Stefani, H. Soininen, J. Schröder, L.M. Shaw, A. Skinningsrud, B. Skrogstad, A. Spreer, L. Talib, C. Teunissen, J.Q. Trojanowski, H. Tumani, R.M. Umek, B. Van Broeck, H. Vanderstichele, L. Vecsei, M.M. Verbeek, M. Windisch, J. Zhang, H. Zetterberg, K. Blennow. - In: ALZHEIMER'S & DEMENTIA. - ISSN 1552-5260. - 7:4(2011), pp. 386-395.

The Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers

D. Galimberti;E. Scarpini;
2011

Abstract

Background: The cerebrospinal fluid (CSF) biomarkers amyloid β (Aβ)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer's disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer's Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for Aβ, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Mölndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure Aβ-(1-42), P-tau(181P), and T-tau), and 5 used Meso Scale Discovery with the Aβ triplex (AβN-42, AβN-40, and AβN-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers.
English
Settore MED/26 - Neurologia
Articolo
Sì, ma tipo non specificato
2011
7
4
386
395
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
The Alzheimer's Association external quality control program for cerebrospinal fluid biomarkers / N. Mattsson, U. Andreasson, S. Persson, H. Arai, S.D. Batish, S. Bernardini, L. Bocchio-Chiavetto, M.A. Blankenstein, M.C. Carrillo, S. Chalbot, E. Coart, D. Chiasserini, N. Cutler, G. Dahlfors, S. Duller, A.M. Fagan, O. Forlenza, G.B. Frisoni, D. Galasko, D. Galimberti, H. Hampel, A. Handberg, M.T. Heneka, A.Z. Herskovits, S.K. Herukka, D.M. Holtzman, C. Humpel, B.T. Hyman, K. Iqbal, M. Jucker, S.A. Kaeser, E. Kaiser, E. Kapaki, D. Kidd, P. Klivenyi, C.S. Knudsen, M.P. Kummer, J. Lui, A. Lladó, P. Lewczuk, Q.X. Li, R. Martins, C. Masters, J. McAuliffe, M. Mercken, A. Moghekar, J.L. Molinuevo, T.J. Montine, W. Nowatzke, R. O'Brien, M. Otto, G.P. Paraskevas, L. Parnetti, R.C. Petersen, D. Prvulovic, H.P. de Reus, R.A. Rissman, E. Scarpini, A. Stefani, H. Soininen, J. Schröder, L.M. Shaw, A. Skinningsrud, B. Skrogstad, A. Spreer, L. Talib, C. Teunissen, J.Q. Trojanowski, H. Tumani, R.M. Umek, B. Van Broeck, H. Vanderstichele, L. Vecsei, M.M. Verbeek, M. Windisch, J. Zhang, H. Zetterberg, K. Blennow. - In: ALZHEIMER'S & DEMENTIA. - ISSN 1552-5260. - 7:4(2011), pp. 386-395.
none
Prodotti della ricerca::01 - Articolo su periodico
78
262
Article (author)
si
N. Mattsson, U. Andreasson, S. Persson, H. Arai, S.D. Batish, S. Bernardini, L. Bocchio-Chiavetto, M.A. Blankenstein, M.C. Carrillo, S. Chalbot, E. Coart, D. Chiasserini, N. Cutler, G. Dahlfors, S. Duller, A.M. Fagan, O. Forlenza, G.B. Frisoni, D. Galasko, D. Galimberti, H. Hampel, A. Handberg, M.T. Heneka, A.Z. Herskovits, S.K. Herukka, D.M. Holtzman, C. Humpel, B.T. Hyman, K. Iqbal, M. Jucker, S.A. Kaeser, E. Kaiser, E. Kapaki, D. Kidd, P. Klivenyi, C.S. Knudsen, M.P. Kummer, J. Lui, A. Lladó, P. Lewczuk, Q.X. Li, R. Martins, C. Masters, J. McAuliffe, M. Mercken, A. Moghekar, J.L. Molinuevo, T.J. Montine, W. Nowatzke, R. O'Brien, M. Otto, G.P. Paraskevas, L. Parnetti, R.C. Petersen, D. Prvulovic, H.P. de Reus, R.A. Rissman, E. Scarpini, A. Stefani, H. Soininen, J. Schröder, L.M. Shaw, A. Skinningsrud, B. Skrogstad, A. Spreer, L. Talib, C. Teunissen, J.Q. Trojanowski, H. Tumani, R.M. Umek, B. Van Broeck, H. Vanderstichele, L. Vecsei, M.M. Verbeek, M. Windisch, J. Zhang, H. Zetterberg, K. Blennow
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/163514
Citazioni
  • ???jsp.display-item.citation.pmc??? 129
  • Scopus 346
  • ???jsp.display-item.citation.isi??? 326
social impact