Background Conventional analysis of exercise electrocardiogram (EX-ECG) has limited accuracy. This study aims to evaluate the potential impact of improving EX-ECG accuracy on costs of diagnosis and number of misdiagnoses of coronary artery disease (CAD). Methods A decision-tree model was simulated including sequential application of diagnostic procedures for suspected CAD. The model was structured in two main branches (presence or absence of CAD). A probabilistic sensitivity analysis was then performed for several combinations of improvement in test sensitivity and specificity. Results A clear trend in cost reduction was observed at improving EX-ECG specificity (about 8-8.5 million dollars, corresponding to a 5.6-7.6% reduction according to the prevalence level). Wrong diagnoses counted for 9-13% of test. Improvements in test parameters lead to reductions in wrong diagnoses, especially when increasing specificity (8.8-12.5%). Conclusions A proper improvement in EX-ECG sensitivity and specificity would have a relevant impact on the costs of CAD management, while reducing the number of misdiagnoses.

Impact of advanced exercise ECG analysis on cost of coronary artery disease management / R. Bigi, A. Ferrando, E. Pagano, L. Cortigiani, F. Merletti, C. Fiorentini, D. Gregori. - In: JOURNAL OF EVALUATION IN CLINICAL PRACTICE. - ISSN 1356-1294. - 16:4(2010 Aug), pp. 678-684. [10.1111/j.1365-2753.2009.01173.x]

Impact of advanced exercise ECG analysis on cost of coronary artery disease management

R. Bigi;C. Fiorentini;
2010

Abstract

Background Conventional analysis of exercise electrocardiogram (EX-ECG) has limited accuracy. This study aims to evaluate the potential impact of improving EX-ECG accuracy on costs of diagnosis and number of misdiagnoses of coronary artery disease (CAD). Methods A decision-tree model was simulated including sequential application of diagnostic procedures for suspected CAD. The model was structured in two main branches (presence or absence of CAD). A probabilistic sensitivity analysis was then performed for several combinations of improvement in test sensitivity and specificity. Results A clear trend in cost reduction was observed at improving EX-ECG specificity (about 8-8.5 million dollars, corresponding to a 5.6-7.6% reduction according to the prevalence level). Wrong diagnoses counted for 9-13% of test. Improvements in test parameters lead to reductions in wrong diagnoses, especially when increasing specificity (8.8-12.5%). Conclusions A proper improvement in EX-ECG sensitivity and specificity would have a relevant impact on the costs of CAD management, while reducing the number of misdiagnoses.
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
ago-2010
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/162228
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact