Background: The aim of this study was to assess the accuracy of a comprehensive multidetector computed tomography (MDCT) evaluation of the aortic annulus (AoA), coronary artery disease (CAD), and peripheral vessels in patients referred for transcatheter aortic valve implantation (TAVI). Methods: In 60 patients referred for TAVI, the following parameters were assessed with 64-slices MDCT and compared with transesophageal echocardiography (TEE), invasive coronary angiography (ICA), and peripheral angiography: AoA maximum diameter (Max-AoA-D MDCT), minimum diameter (Min-AoA-D MDCT), and area; lumen morphology index ([Max-AoA-D MDCT/Min-AoA-D MDCT]); length of the left, right, and non-coronary aortic leaflets; degree (grades 1-4) of aortic leaflet calcifications; distance between AoA and left main coronary ostium and between AoA and right coronary ostium CAD and peripheral vessel disease. Results: The Max-AoA-D MDCT and Min-AoA-D MDCT were 25.1 ± 2.8 and 21.2 ± 2.2 mm, respectively, with high correlation versus AoA diameter measured with TEE (r = 0.82 and 0.86, respectively). The area of AoA, systolic and diastolic lumen morphology index were 410 ± 81.5 mm 2, 1.19 ± 0.1 and 1.22 ± 0.11, respectively. Aortic leaflet calcification score was 3.3 ± 0.5. The lengths of left, right, and non-coronary aortic leaflets were 14.2 ± 2.4, 13.7.1 ± 2.1, and 14.5 ± 2.6 mm, whereas distances between AoA and the left main coronary ostium and between AoA, and the right coronary ostium were 13.7 ± 2.9 and 15.8 ± 3.5 mm, respectively. Feasibility, negative predictive value, and accuracy for CAD detection versus ICA were 87%, 100% (CI 100-100), and 96% (95% CI 94-100), respectively. All patients (N = 17) who were ineligible for TAVI were correctly detected by MDCT. Conclusions: A comprehensive MDCT evaluation of patients referred for TAVI is feasible, provides more accurate assessment than TEE of AoA morphology, and may replace peripheral angiography in all patients and ICA in patients without significant CAD.

Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation / G. Pontone, D. Andreini, A. Bartorelli, A. Annoni, S. Mushtaq, E. Bertella, A. Formenti, S. Cortinovis, F. Alamanni, M. Fusari, V. Bona, G. Tamborini, M. Muratori, G. Ballerini, C. Fiorentini, P. Biglioli, M. Pepi. - In: AMERICAN HEART JOURNAL. - ISSN 0002-8703. - 161:6(2011 Jun), pp. 1106-1113. [10.1016/j.ahj.2011.03.003]

Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation

G. Pontone;D. Andreini;A. Bartorelli;S. Mushtaq;E. Bertella;S. Cortinovis;F. Alamanni;C. Fiorentini;
2011

Abstract

Background: The aim of this study was to assess the accuracy of a comprehensive multidetector computed tomography (MDCT) evaluation of the aortic annulus (AoA), coronary artery disease (CAD), and peripheral vessels in patients referred for transcatheter aortic valve implantation (TAVI). Methods: In 60 patients referred for TAVI, the following parameters were assessed with 64-slices MDCT and compared with transesophageal echocardiography (TEE), invasive coronary angiography (ICA), and peripheral angiography: AoA maximum diameter (Max-AoA-D MDCT), minimum diameter (Min-AoA-D MDCT), and area; lumen morphology index ([Max-AoA-D MDCT/Min-AoA-D MDCT]); length of the left, right, and non-coronary aortic leaflets; degree (grades 1-4) of aortic leaflet calcifications; distance between AoA and left main coronary ostium and between AoA and right coronary ostium CAD and peripheral vessel disease. Results: The Max-AoA-D MDCT and Min-AoA-D MDCT were 25.1 ± 2.8 and 21.2 ± 2.2 mm, respectively, with high correlation versus AoA diameter measured with TEE (r = 0.82 and 0.86, respectively). The area of AoA, systolic and diastolic lumen morphology index were 410 ± 81.5 mm 2, 1.19 ± 0.1 and 1.22 ± 0.11, respectively. Aortic leaflet calcification score was 3.3 ± 0.5. The lengths of left, right, and non-coronary aortic leaflets were 14.2 ± 2.4, 13.7.1 ± 2.1, and 14.5 ± 2.6 mm, whereas distances between AoA and the left main coronary ostium and between AoA, and the right coronary ostium were 13.7 ± 2.9 and 15.8 ± 3.5 mm, respectively. Feasibility, negative predictive value, and accuracy for CAD detection versus ICA were 87%, 100% (CI 100-100), and 96% (95% CI 94-100), respectively. All patients (N = 17) who were ineligible for TAVI were correctly detected by MDCT. Conclusions: A comprehensive MDCT evaluation of patients referred for TAVI is feasible, provides more accurate assessment than TEE of AoA morphology, and may replace peripheral angiography in all patients and ICA in patients without significant CAD.
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Settore MED/23 - Chirurgia Cardiaca
Settore MED/36 - Diagnostica per Immagini e Radioterapia
giu-2011
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/159201
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 70
social impact