von Willebrand's disease (VWD) is regarded as the most common congenital bleeding disorder, and although not available in all laboratories von Willebrand factor (VWF) activity is most frequently assessed as ristocetin cofactor (VWF:RCo). This test can be technically challenging, is subject to poor sensitivity (∼20 IU dL(-1) VWF:RCo) and has a high degree of inter- and intra-assay imprecision [coefficient of variation (cv) > 25%]. We studied an automated assay using a combined fixed platelet/ristocetin reagent (BC von Willebrand reagent, Siemens Healthcare Diagnostics) on the CS-2000i analyser (Sysmex UK Ltd). Initially inter- and intra-assay imprecision was assessed. The automated method showed good day-to-day reproducibility and linearity of standard curves. This technique, also gave low intra- and inter-assay imprecision using commercial normal (cv < 4.5%) and pathological (cv < 8.1%) control plasmas. We then compared automated technique results from 30 healthy normal subjects and 39 VWD patients to those obtained using standard aggregometry (Bio/Data, PAP4) with lyophilised fixed platelets (Helena BioSciences) and ristocetin (American Biochemical and Pharmaceutical Ltd). The automated method had a sensitivity limit of approximately 10 IU dL(-1) vs. 20 IU dL(-1) for aggregometry. Samples giving results within the aggregometry measurable range (n = 50) exhibited good correlation with the automated technique (median 70 IU dL(-1), range 7-184 IU dL(-1); and 64 IU dL(-1), 6-138 IU dL(-1) respectively; R(2) = 0.85). We subsequently compared 3 different batches of BC von Willebrand reagent, using a second group of normal subjects and VWD patients (n = 35, 55-139 IU dL(-1) and n = 30, <10-50 IU dL(-1)). The CS-2000i results exhibited no clinically significant variation between batches (mean cv = 7%). The automated VWF:RCo assay offers a more sensitive, reproducible, robust and less laborious alternative to standard aggregometry

Evaluation of an automated platelet-based assay of ristocetin cofactor activity / A.S. Lawrie, I.J. Mackie, S.J. Machin, F. Peyvandi. - In: HAEMOPHILIA. - ISSN 1351-8216. - 17:2(2011 Mar), pp. 252-256.

Evaluation of an automated platelet-based assay of ristocetin cofactor activity

F. Peyvandi
Ultimo
2011

Abstract

von Willebrand's disease (VWD) is regarded as the most common congenital bleeding disorder, and although not available in all laboratories von Willebrand factor (VWF) activity is most frequently assessed as ristocetin cofactor (VWF:RCo). This test can be technically challenging, is subject to poor sensitivity (∼20 IU dL(-1) VWF:RCo) and has a high degree of inter- and intra-assay imprecision [coefficient of variation (cv) > 25%]. We studied an automated assay using a combined fixed platelet/ristocetin reagent (BC von Willebrand reagent, Siemens Healthcare Diagnostics) on the CS-2000i analyser (Sysmex UK Ltd). Initially inter- and intra-assay imprecision was assessed. The automated method showed good day-to-day reproducibility and linearity of standard curves. This technique, also gave low intra- and inter-assay imprecision using commercial normal (cv < 4.5%) and pathological (cv < 8.1%) control plasmas. We then compared automated technique results from 30 healthy normal subjects and 39 VWD patients to those obtained using standard aggregometry (Bio/Data, PAP4) with lyophilised fixed platelets (Helena BioSciences) and ristocetin (American Biochemical and Pharmaceutical Ltd). The automated method had a sensitivity limit of approximately 10 IU dL(-1) vs. 20 IU dL(-1) for aggregometry. Samples giving results within the aggregometry measurable range (n = 50) exhibited good correlation with the automated technique (median 70 IU dL(-1), range 7-184 IU dL(-1); and 64 IU dL(-1), 6-138 IU dL(-1) respectively; R(2) = 0.85). We subsequently compared 3 different batches of BC von Willebrand reagent, using a second group of normal subjects and VWD patients (n = 35, 55-139 IU dL(-1) and n = 30, <10-50 IU dL(-1)). The CS-2000i results exhibited no clinically significant variation between batches (mean cv = 7%). The automated VWF:RCo assay offers a more sensitive, reproducible, robust and less laborious alternative to standard aggregometry
Settore MED/09 - Medicina Interna
mar-2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
j.1365-2516.2010.02419.x.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 181.23 kB
Formato Adobe PDF
181.23 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/156675
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 20
social impact