Background: Several assays are now available to evaluate platelet-dependent von Willebrand factor (VWF) activity. Objective: To report the results obtained using 4 different assays in patients with von Willebrand disease (VWD) carrying variants mainly in the A1 domain, which is critical for VWF binding to glycoprotein Ib (GPIb) and ristocetin. Methods: We evaluated 4 different assays, 2 gain-of-function mutant GPIb binding (VWF:GPIbM) and 2 ristocetin cofactor (VWF:RCo) assays, in 76 patients with type 2 VWD. Patients and healthy controls were tested using VWF:GPIbM enzyme-linked immunosorbent assay (ELISA), VWF:GPIbM automated, VWF:RCo aggregometric, and VWF:RCo automated assays. Results: There was a good correlation (Pearson's r>0.82) and agreement (Bland-Altman plots assessment) between the 4 assays, although several outliers existed among the type 2B without high-molecular-weight multimers (HMWM). The VWF activity/VWF:antigen ratios, calculated for each assay, were used to establish the percentage of a correct diagnosis of type 2 (ratio<0.60) in these patients: VWF:RCo aggregometric, 2A(100%), 2M(78%), 2M/2A(100%), 2B(68%); VWF:RCo automated, 2A(88%), 2M(89%), 2M/2A(100%), 2B(63%); VWF:GPIbM ELISA, 2A(96%), 2M(67%), 2M/2A(67%), 2B(0%); VWF:GPIbM automated, 2A(73%), 2M(44%), 2M/2A(75%), 2B(84%). In type 2B patients with HMWM, all assays gave a ratio ≥0.60. Conclusion: The VWF:GPIbM-automated assay is the most effective to diagnose as type 2 the 2B variants, whereas the VWF:RCo assays are the most effective in detecting 2M and 2M/2A variants. The VWF:GPIbM ELISA greatly overestimates the activity of the type 2B patients lacking HMWM. In this study, the use of a VWF activity/VWF:antigen ratio cut-off of 0.70 halved the number of misdiagnosed patients.

A comparative study in patients with type 2 von Willebrand disease using 4 different platelet-dependent von Willebrand factor assays / P. Colpani, L.B.. - In: RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS. - ISSN 2475-0379. - 7:3(2023 Mar), pp. 100139.1-100139.13. [10.1016/j.rpth.2023.100139]

A comparative study in patients with type 2 von Willebrand disease using 4 different platelet-dependent von Willebrand factor assays

L. Baronciani
Co-primo
;
M. Boscarino;M.T. Pagliari;F. Peyvandi
Ultimo
2023

Abstract

Background: Several assays are now available to evaluate platelet-dependent von Willebrand factor (VWF) activity. Objective: To report the results obtained using 4 different assays in patients with von Willebrand disease (VWD) carrying variants mainly in the A1 domain, which is critical for VWF binding to glycoprotein Ib (GPIb) and ristocetin. Methods: We evaluated 4 different assays, 2 gain-of-function mutant GPIb binding (VWF:GPIbM) and 2 ristocetin cofactor (VWF:RCo) assays, in 76 patients with type 2 VWD. Patients and healthy controls were tested using VWF:GPIbM enzyme-linked immunosorbent assay (ELISA), VWF:GPIbM automated, VWF:RCo aggregometric, and VWF:RCo automated assays. Results: There was a good correlation (Pearson's r>0.82) and agreement (Bland-Altman plots assessment) between the 4 assays, although several outliers existed among the type 2B without high-molecular-weight multimers (HMWM). The VWF activity/VWF:antigen ratios, calculated for each assay, were used to establish the percentage of a correct diagnosis of type 2 (ratio<0.60) in these patients: VWF:RCo aggregometric, 2A(100%), 2M(78%), 2M/2A(100%), 2B(68%); VWF:RCo automated, 2A(88%), 2M(89%), 2M/2A(100%), 2B(63%); VWF:GPIbM ELISA, 2A(96%), 2M(67%), 2M/2A(67%), 2B(0%); VWF:GPIbM automated, 2A(73%), 2M(44%), 2M/2A(75%), 2B(84%). In type 2B patients with HMWM, all assays gave a ratio ≥0.60. Conclusion: The VWF:GPIbM-automated assay is the most effective to diagnose as type 2 the 2B variants, whereas the VWF:RCo assays are the most effective in detecting 2M and 2M/2A variants. The VWF:GPIbM ELISA greatly overestimates the activity of the type 2B patients lacking HMWM. In this study, the use of a VWF activity/VWF:antigen ratio cut-off of 0.70 halved the number of misdiagnosed patients.
enzyme-linked immunosorbent assay; gain-of-function mutation; glycoprotein Ib alpha; Ristocetin-Willebrand factor; von Willebrand disease; von Willebrand factor;
Settore MEDS-05/A - Medicina interna
mar-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
Colpani RPTH.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 2.57 MB
Formato Adobe PDF
2.57 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1255055
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
  • OpenAlex 7
social impact