Aim: To compare directly printed aligners (DPA) and thermoformed aligners (TFA), evaluating the potential release and dispersion of microplastic (MP) and nanoplastic (NP) particles under simulated oral conditions. Materials and methods: DPA samples (Graphy Tera Harz TC-85-DAC resin) and TFA samples (Invisalign® SmartTrack) were subjected to rubs in an ultrapure water bath. The liquid was collected post-friction and analyzed for MPs and NPs using various techniques: optical microscopy (OM), transmission electron microscopy (TEM), and atomic force microscopy (AFM). Also, plastic residues were quantified by weighing after drying within a laminar flow hood. Microscopic image analyses comprised the quantification of the average size of MPs and NPs, their concentration by TEM, and the roughness analysis by AFM. Results: The masses of MPs and NPs separated after rubbing were 0.001 g/200 μl and 0.004 g/200 μl for TFA and DPA samples, respectively. TEM analysis confirmed that DPA samples had larger (203.08â€...±â€...2651.65 μm²) and more numerous particles compared to TFA (0.23â€...±â€...27.53 μm²), even though it was not possible to distinguish the MPs and NPs due to clustering of the plastic residuals. AFM analysis indicated a bigger root mean square grain size for TFA than DPA; similarly, the mean roughness was lesser in the DPA sample than TFA one. Conclusions: DPA generated larger and more numerous plastic particles compared to TFA, though grain-size characterization was challenging due to particle aggregation. This suggests that the manufacturing process and materials used in DPA could impact the creation of MPs and NPs during simulated mastication, highlighting a potential area for process optimization.

Comparative microscopic analysis of plastic dispersion from 3D-printed and thermoformed orthodontic aligners / P. Antonio Zecca, M. Borgese, M. Raspanti, F. Zara, R. Fastuca, M. Serafin, A. Caprioglio. - 47:3(2025 Jun), pp. cjaf014.1-cjaf014.8. [10.1093/ejo/cjaf014]

Comparative microscopic analysis of plastic dispersion from 3D-printed and thermoformed orthodontic aligners

F. Zara;M. Serafin
;
A. Caprioglio
Ultimo
2025

Abstract

Aim: To compare directly printed aligners (DPA) and thermoformed aligners (TFA), evaluating the potential release and dispersion of microplastic (MP) and nanoplastic (NP) particles under simulated oral conditions. Materials and methods: DPA samples (Graphy Tera Harz TC-85-DAC resin) and TFA samples (Invisalign® SmartTrack) were subjected to rubs in an ultrapure water bath. The liquid was collected post-friction and analyzed for MPs and NPs using various techniques: optical microscopy (OM), transmission electron microscopy (TEM), and atomic force microscopy (AFM). Also, plastic residues were quantified by weighing after drying within a laminar flow hood. Microscopic image analyses comprised the quantification of the average size of MPs and NPs, their concentration by TEM, and the roughness analysis by AFM. Results: The masses of MPs and NPs separated after rubbing were 0.001 g/200 μl and 0.004 g/200 μl for TFA and DPA samples, respectively. TEM analysis confirmed that DPA samples had larger (203.08â€...±â€...2651.65 μm²) and more numerous particles compared to TFA (0.23â€...±â€...27.53 μm²), even though it was not possible to distinguish the MPs and NPs due to clustering of the plastic residuals. AFM analysis indicated a bigger root mean square grain size for TFA than DPA; similarly, the mean roughness was lesser in the DPA sample than TFA one. Conclusions: DPA generated larger and more numerous plastic particles compared to TFA, though grain-size characterization was challenging due to particle aggregation. This suggests that the manufacturing process and materials used in DPA could impact the creation of MPs and NPs during simulated mastication, highlighting a potential area for process optimization.
direct printed aligners; microscopy analysis; microsplastics; nanoplastics; thermoformed aligners
Settore MEDS-16/A - Malattie odontostomatologiche
Settore BIOS-12/A - Anatomia umana
giu-2025
11-apr-2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
5df2ff93-c9f6-4e49-8dd8-30d543ca2431.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 782.04 kB
Formato Adobe PDF
782.04 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1206558
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 4
social impact