Wastewater-based environmental surveillance enables the monitoring of SARS- CoV-2 dynamics within populations, offering critical epidemiological insights. Numer- ous workflows for tracking SARS-CoV-2 have been developed globally, underscoring the need for interlaboratory comparisons to ensure data consistency and comparability. An inter-calibration test was conducted among laboratories within the network monitoring SARS-CoV-2 in wastewater samples across the Lombardy region (Italy). The test aimed to evaluate data reliability and identify potential sources of variability using robust statistical approaches. Three wastewater samples were analyzed in parallel by four laboratories using identical pre-analytical (PEG-8000-based centrifugation) and analytical processes (qPCR targeting N1/N3 and Orf-1ab). A two-way ANOVA framework within Generalized Linear Models was applied, and multiple pairwise comparisons among laboratories were per- formed using the Bonferroni post hoc test. The statistical analysis revealed that the primary source of variability in the results was associated with the analytical phase. This variability was likely influenced by differences in the standard curves used by the laboratories to quantify SARS-CoV-2 concentrations, as well as the size of the wastewater treatment plants. The findings of this study highlight the importance of interlaboratory testing in verifying the consistency of analytical determinations and in identifying the key sources of variation.
Evaluating Interlaboratory Variability in Wastewater-Based COVID-19 Surveillance / A. Azzellino, L. Pellegrinelli, R. Pedrini, A. Turolla, B. Bertasi, S. Binda, S. Castiglioni, C.E. Cocuzza, F. Ferrari, A. Franzetti, M.G. Guiso, M.N. Losio, M. Martinelli, A. Martines, R. Musumeci, D. Oliva, L. Sandri, V. Primache, F. Righi, A. Scarazzato, S. Schiarea, E. Pariani, E. Ammoni, D. Cereda, F. Malpei. - In: MICROORGANISMS. - ISSN 2076-2607. - 13:3(2025 Feb), pp. 526.1-526.20. [10.3390/microorganisms13030526]
Evaluating Interlaboratory Variability in Wastewater-Based COVID-19 Surveillance
L. PellegrinelliSecondo
;S. Binda;L. Sandri;V. Primache;E. Pariani;
2025
Abstract
Wastewater-based environmental surveillance enables the monitoring of SARS- CoV-2 dynamics within populations, offering critical epidemiological insights. Numer- ous workflows for tracking SARS-CoV-2 have been developed globally, underscoring the need for interlaboratory comparisons to ensure data consistency and comparability. An inter-calibration test was conducted among laboratories within the network monitoring SARS-CoV-2 in wastewater samples across the Lombardy region (Italy). The test aimed to evaluate data reliability and identify potential sources of variability using robust statistical approaches. Three wastewater samples were analyzed in parallel by four laboratories using identical pre-analytical (PEG-8000-based centrifugation) and analytical processes (qPCR targeting N1/N3 and Orf-1ab). A two-way ANOVA framework within Generalized Linear Models was applied, and multiple pairwise comparisons among laboratories were per- formed using the Bonferroni post hoc test. The statistical analysis revealed that the primary source of variability in the results was associated with the analytical phase. This variability was likely influenced by differences in the standard curves used by the laboratories to quantify SARS-CoV-2 concentrations, as well as the size of the wastewater treatment plants. The findings of this study highlight the importance of interlaboratory testing in verifying the consistency of analytical determinations and in identifying the key sources of variation.| File | Dimensione | Formato | |
|---|---|---|---|
|
microorganisms-13-00526.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Licenza:
Creative commons
Dimensione
2.79 MB
Formato
Adobe PDF
|
2.79 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




