Objectives Glucose monitoring in diabetes is changing overtime with a constant development of new devices for continuous glucose monitoring (CGM). Aim of this observational, prospective study was to evaluate the clinical performance of a novel intermittently scanned CGM system, the Glunovo Flash in a cohort of patients with type 1 diabetes. Methods A total of 45 patients with T1D followed at the Endocrinology Unit of the ASST-FBF-Sacco (Milan) were enrolled. All patients were habitual CGM users and were asked to wear simultaneously the Glunovo Flash system and their habitual CGM device for 14 days. A comparison of CGM glucose metrics was performed. Patients’ opinions on the new device were also collected. Results Thirty-five patients completed the study period of two weeks (7 habitual real time CGM users, 28 habitual inter- mittently scanned CGM users). Mean Time In Range resulted significantly higher with the novel studied sensor respect to intermittently scanned CGM comparator. No differences were found considering other glucose metrics. A positive correlation was found between the Time In Range recorded by Glunovo Flash and intermittently scanned CGM comparators as well as for Time Above Range, Glucose Management Indicator, Time Below Range and Coefficient of Variation. No correlations were found between glucose metrics recorded by Glunovo Flash and real time CGM comparators. Patients reported a posi- tive experience of use with the new sensor but some elements appeared improvable. Conclusions The CGM device Glunovo Flash for patients with diabetes shows similar performance to other intermittently scanned CGM systems.

A new glucose monitoring system for the intermittent monitoring of interstitial glucose values in patients with diabetes mellitus / A. Rossi, G. Rossi, L. Montefusco, V. Cimino, I. Pastore, A. Gandolfi, L. Bucciarelli, C. Loretelli, D. Boci, F. D'Addio, M.E. Lunati, P. Fiorina. - In: JOURNAL OF DIABETES AND METABOLIC DISORDERS. - ISSN 2251-6581. - (2024), pp. 1-5. [Epub ahead of print] [10.1007/s40200-024-01488-2]

A new glucose monitoring system for the intermittent monitoring of interstitial glucose values in patients with diabetes mellitus

A. Rossi
Primo
;
G. Rossi
Secondo
;
L. Montefusco;V. Cimino;I. Pastore;L. Bucciarelli;C. Loretelli;F. D'Addio;M.E. Lunati;P. Fiorina
Ultimo
2024

Abstract

Objectives Glucose monitoring in diabetes is changing overtime with a constant development of new devices for continuous glucose monitoring (CGM). Aim of this observational, prospective study was to evaluate the clinical performance of a novel intermittently scanned CGM system, the Glunovo Flash in a cohort of patients with type 1 diabetes. Methods A total of 45 patients with T1D followed at the Endocrinology Unit of the ASST-FBF-Sacco (Milan) were enrolled. All patients were habitual CGM users and were asked to wear simultaneously the Glunovo Flash system and their habitual CGM device for 14 days. A comparison of CGM glucose metrics was performed. Patients’ opinions on the new device were also collected. Results Thirty-five patients completed the study period of two weeks (7 habitual real time CGM users, 28 habitual inter- mittently scanned CGM users). Mean Time In Range resulted significantly higher with the novel studied sensor respect to intermittently scanned CGM comparator. No differences were found considering other glucose metrics. A positive correlation was found between the Time In Range recorded by Glunovo Flash and intermittently scanned CGM comparators as well as for Time Above Range, Glucose Management Indicator, Time Below Range and Coefficient of Variation. No correlations were found between glucose metrics recorded by Glunovo Flash and real time CGM comparators. Patients reported a posi- tive experience of use with the new sensor but some elements appeared improvable. Conclusions The CGM device Glunovo Flash for patients with diabetes shows similar performance to other intermittently scanned CGM systems.
Continuous glucose monitoring; Diabetes management system; Flash glucose monitoring; Device satisfaction type 1 diabetes
Settore MED/13 - Endocrinologia
Settore MEDS-08/A - Endocrinologia
2024
9-set-2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
A new glucose monitoring system for the intermittent monitoring of interstitial glucose values in patients with diabetes mellitus.pdf

accesso riservato

Descrizione: Online First
Tipologia: Publisher's version/PDF
Dimensione 840.4 kB
Formato Adobe PDF
840.4 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1096628
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact