A 62-year-old woman with porto-sinusoidal vascular disorder and portal hypertension was admitted to the emergency department for hematemesis and anemia (hemoglobin 8.1 mg/dL). Five years ago, she had been treated at another hospital with two sessions of endoscopic variceal ligation (EVL) for esophageal variceal bleeding. After hemodynamic stabilization, an upper gastrointestinal endoscopy was performed and large-caliber esophageal varices with red signs were found in the middle and lower third of the esophagus. There was no active bleeding. EVL (Speedband Superview Super 7; Boston Scientific, Marlborough, Massachusetts, United States) was performed [1], but the placement of one of the bands failed due to poor tissue elevation, causing accidental oozing bleeding. Another band was promptly placed achieving hemostasis, but the position of the band was suboptimal due to inadequate tissue elevation. The small amount of variceal tissue grasped by the band could have caused premature band dislodgement and severe post-banding ulcer bleeding. Therefore, we placed the banding cap over the misplaced band ([Fig. 1]) and applied prolonged suction to achieve maximal tissue prolapse inside the banding cap ([Video 1]). Finally, we placed a new band below the previous one ([Fig. 2]). Such band-on-band EVL was successful, achieving optimal band placement without residual bleeding. No further adverse events occurred and the patient was discharged home 4 days after admission. At a 1-month follow-up visit, no adverse events or rebleeding were reported.
Band-on-band endoscopic variceal ligation: a technique for the treatment of esophageal varices in case of band misplacement / A. Sorge, T. Pessarelli, L. Elli, N. Nandi, G. Tosetti, M. Primignani, G.E. Tontini. - In: ENDOSCOPY. - ISSN 0013-726X. - 56:s1(2024 Dec), pp. E211-E212. [10.1055/a-2268-5513]
Band-on-band endoscopic variceal ligation: a technique for the treatment of esophageal varices in case of band misplacement
A. Sorge
Primo
;T. PessarelliSecondo
;L. Elli;N. Nandi;G. Tosetti;G.E. TontiniUltimo
2024
Abstract
A 62-year-old woman with porto-sinusoidal vascular disorder and portal hypertension was admitted to the emergency department for hematemesis and anemia (hemoglobin 8.1 mg/dL). Five years ago, she had been treated at another hospital with two sessions of endoscopic variceal ligation (EVL) for esophageal variceal bleeding. After hemodynamic stabilization, an upper gastrointestinal endoscopy was performed and large-caliber esophageal varices with red signs were found in the middle and lower third of the esophagus. There was no active bleeding. EVL (Speedband Superview Super 7; Boston Scientific, Marlborough, Massachusetts, United States) was performed [1], but the placement of one of the bands failed due to poor tissue elevation, causing accidental oozing bleeding. Another band was promptly placed achieving hemostasis, but the position of the band was suboptimal due to inadequate tissue elevation. The small amount of variceal tissue grasped by the band could have caused premature band dislodgement and severe post-banding ulcer bleeding. Therefore, we placed the banding cap over the misplaced band ([Fig. 1]) and applied prolonged suction to achieve maximal tissue prolapse inside the banding cap ([Video 1]). Finally, we placed a new band below the previous one ([Fig. 2]). Such band-on-band EVL was successful, achieving optimal band placement without residual bleeding. No further adverse events occurred and the patient was discharged home 4 days after admission. At a 1-month follow-up visit, no adverse events or rebleeding were reported.File | Dimensione | Formato | |
---|---|---|---|
a-2268-5513.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Dimensione
950.78 kB
Formato
Adobe PDF
|
950.78 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.