This research was aimed at setting up an analytical method for the determination in pork products of 4-hydroxy-2-nonenal (4-HNE), an aldehyde produced from the oxidation of omega-6-polyunsaturated fatty acids. Such a compound mediates various biological effects, but it is considered to be very toxic to mammalian cells at levels higher than physiological ones. The methods used for the determination of 4-HNE in biological fluids, such as blood, were found to be unsuitable for meat samples because both the repeatability and the recovery in spiked samples were unsatisfactory. A new method, based on solid phase extraction and HPLC-MS/MS, was therefore developed and validated. The limit of detection of 4-HNE in spiked samples was 0.043 mg/kg, and the recovery was approximately 60% depending on the concentration. Good linearity was observed in the range of 0.1-10 mg/kg, and repeatability and interday and intraday precision expressed as relative standard deviation were <10%. The method has been successfully applied to the determination of the aldehyde in samples of various pork products. 4-HNE was present in some products, especially the smoked and/or cooked ones, at levels that might not be a real risk for human health.

Solid phase extraction and liquid chromatography-tandem mass spectrometry for the evaluation of 4-hydroxy-2-nonenal in pork products / E. Zanardi, C. Jagersma, S. Ghidini, R. Chizzolini. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - 50:19(2002), pp. 5268-5272. [10.1021/jf020201h]

Solid phase extraction and liquid chromatography-tandem mass spectrometry for the evaluation of 4-hydroxy-2-nonenal in pork products

S. Ghidini
Penultimo
;
2002

Abstract

This research was aimed at setting up an analytical method for the determination in pork products of 4-hydroxy-2-nonenal (4-HNE), an aldehyde produced from the oxidation of omega-6-polyunsaturated fatty acids. Such a compound mediates various biological effects, but it is considered to be very toxic to mammalian cells at levels higher than physiological ones. The methods used for the determination of 4-HNE in biological fluids, such as blood, were found to be unsuitable for meat samples because both the repeatability and the recovery in spiked samples were unsatisfactory. A new method, based on solid phase extraction and HPLC-MS/MS, was therefore developed and validated. The limit of detection of 4-HNE in spiked samples was 0.043 mg/kg, and the recovery was approximately 60% depending on the concentration. Good linearity was observed in the range of 0.1-10 mg/kg, and repeatability and interday and intraday precision expressed as relative standard deviation were <10%. The method has been successfully applied to the determination of the aldehyde in samples of various pork products. 4-HNE was present in some products, especially the smoked and/or cooked ones, at levels that might not be a real risk for human health.
4-Hydroxy-2-nonenal; Lipid oxidation; Pork products; Safety
Settore VET/04 - Ispezione degli Alimenti di Origine Animale
2002
Article (author)
File in questo prodotto:
File Dimensione Formato  
F:\Word\Articoli\JAgricFoodChem 4 HNE\solidphase.pdf

accesso riservato

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 58.95 kB
Formato Adobe PDF
58.95 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1028455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 29
social impact