This paper presents a source apportionment study performed on a dataset collected at a trafficked site in Coimbra (Portugal) during the period December 2018-June 2019. The novelty of this work consists in the methodological approach used and the sensitivity study carried out to give hints to potential future applications. Indeed, a multi-time resolution and multi-parameter study was performed joining together aerosol data from 24-h chemically characterized samples and high-time resolution multi-wavelength absorption coefficients retrieved by an Aethalometer. A detailed sensitivity study on the most suitable combination of time resolution and uncertainties was carried out to obtain reliable physical and stable solutions over all analyses. In parallel, a regular EPA-PMF source apportionment study using chemical and optical variables averaged on 24 h is presented and discussed in comparison to the more complex multi-time and multi-parameter approach. Apart from results pertaining to the identification and relevance of different sources in Coimbra, the methodological results shown here can give guidance for readers who want to implement optical variables jointly with chemical ones in the same model run.

Insights on the combination of off-line and on-line measurement approaches for source apportionment studies / A.C. Forello, I. Cunha-Lopes, S.M. Almeida, C.A. Alves, O. Tchepel, F. Crova, R. Vecchi. - In: SCIENCE OF THE TOTAL ENVIRONMENT. - ISSN 0048-9697. - 900:(2023 Jul 27), pp. 165860.1-165860.9. [10.1016/j.scitotenv.2023.165860]

Insights on the combination of off-line and on-line measurement approaches for source apportionment studies

A.C. Forello
Primo
;
F. Crova;R. Vecchi
Ultimo
2023

Abstract

This paper presents a source apportionment study performed on a dataset collected at a trafficked site in Coimbra (Portugal) during the period December 2018-June 2019. The novelty of this work consists in the methodological approach used and the sensitivity study carried out to give hints to potential future applications. Indeed, a multi-time resolution and multi-parameter study was performed joining together aerosol data from 24-h chemically characterized samples and high-time resolution multi-wavelength absorption coefficients retrieved by an Aethalometer. A detailed sensitivity study on the most suitable combination of time resolution and uncertainties was carried out to obtain reliable physical and stable solutions over all analyses. In parallel, a regular EPA-PMF source apportionment study using chemical and optical variables averaged on 24 h is presented and discussed in comparison to the more complex multi-time and multi-parameter approach. Apart from results pertaining to the identification and relevance of different sources in Coimbra, the methodological results shown here can give guidance for readers who want to implement optical variables jointly with chemical ones in the same model run.
Multi-time resolution; Optical variables; PM sources; Sensitivity study
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
27-lug-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0048969723044856-main.pdf

accesso riservato

Descrizione: Article
Tipologia: Publisher's version/PDF
Dimensione 4.08 MB
Formato Adobe PDF
4.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/990408
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact